Emerson 1F92 Manuel D’Utilisation

Page de 44
34
feature. Change to the next program
period and press the FAN key until
PR
PR
PR
PR
PRG F
G F
G F
G F
G FAN ON
AN ON
AN ON
AN ON
AN ON is on the display.
The fan will continue to run through
this period as well as the previous
one.
If the thermostat is in a period with
continuous fan and you want the fan
to cycle, press the FAN key. 
PR
PR
PR
PR
PRG
G
G
G
G
FAN ON
FAN ON
FAN ON
FAN ON
FAN ON on the display will turn
off.
Air Filter
Air Filter
Air Filter
Air Filter
Air Filter
Change-Out Indicator.
Change-Out Indicator.
Change-Out Indicator.
Change-Out Indicator.
Change-Out Indicator.
This feature allows the thermostat to
display 
CHNG FLTR
CHNG FLTR
CHNG FLTR
CHNG FLTR
CHNG FLTR (change
filter) after a set time of fan
operation. This is a reminder to
change or clean your air filter. The
factory set interval for 
CHNG
CHNG
CHNG
CHNG
CHNG
FLTR
FLTR
FLTR
FLTR
FLTR to be displayed is 200 hours
of fan operation. This can be set
anywhere from 0 to 1950 hours in
25 hour increments. A selection of
00
00
00
00
00 will cancel this feature.
When 
CHNG FLTR
CHNG FLTR
CHNG FLTR
CHNG FLTR
CHNG FLTR is displayed,
you can clear it by pressing the
FILTER key. This resets the timer
and starts counting the hours until
the next filter change.
The following steps will allow you
to change the number of hours for
filter change-out.
1. If 
CHNG FL
CHNG FL
CHNG FL
CHNG FL
CHNG FLTR
TR
TR
TR
TR is on the display,
press the FILTER key once to reset
the timer. If you do not see 
CHNG
CHNG
CHNG
CHNG
CHNG
FLTR
FLTR
FLTR
FLTR
FLTR proceed to step 2.
2. Press the FILTER key, The
display will show 
SET FIL
SET FIL
SET FIL
SET FIL
SET FILTER
TER
TER
TER
TER
TIME
TIME
TIME
TIME
TIME and the number of hours
remaining before 
CHNG FLTR
CHNG FLTR
CHNG FLTR
CHNG FLTR
CHNG FLTR
indicator will display.
3. Press the FILTER key a second
time. The display will show 
SET
SET
SET
SET
SET
FIL
FIL
FIL
FIL
FILTER 
TER 
TER 
TER 
TER TIME
TIME
TIME
TIME
TIME and will show the
number of hours to filter change.
4. Press TIME 
FWD
 or TIME
BACK
 to change the time to your
requirements.
5. Press PROGRAM 
RUN
 to
return to the normal operating mode.
NOTE: If unsure what interval to
use between filter changes or
cleaning, contact the manufacturer
of your heating/cooling equipment.
System and Thermostat
System and Thermostat
System and Thermostat
System and Thermostat
System and Thermostat
Diagnostics.
Diagnostics.
Diagnostics.
Diagnostics.
Diagnostics.
The display will indicate 
CHECK
CHECK
CHECK
CHECK
CHECK
SYS
SYS
SYS
SYS
SYS if the room temperature does
not rise within two hours of the call
for heat. After two hours the