multi-zone Heat Pump Condensing units
EMI AMErIcA SErIES MultI-zonE HEAt PuMP condEnSIng unItS
• Compressor and Fan Motor Contactor
• Capacitor
• Low Voltage Connections 
• Large Capacity Suction Accumulator (9, 
12, & 18 Only)
• High Pressure Control (18 & 24 Only)
• Solid Core Filter Drier 
• Thermostatically controlled crankcase 
heater 
(9&12 Only)
• Common suction pressure access point 
• Hard Start Capacitor
iTemS For ConSideraTion
• Locate the unit as close to the indoor sec-
tion as possible. Maximum length allowed 
is 100 equivalent feet.
• Avoid high traffic areas and prevailing 
wind locations.
• Surface must be level.
• Mount unit above typical snow levels.
Ensure  free air  flow  through  the  unit. Air 
must not recirculate from discharge to in-
take. Air is drawn through the coil with side 
or top and discharged through the fan grille. 
A minimum 48” clearance is necessary 
for  the  condenser  discharge.  Intake 
(coil  side)  clearance  is  12”  minimum. 
Consider how power will be run to the unit 
from the power source. Refrigerant piping 
must be a direct line to the indoor unit.
Heat pump units produce condensate in the 
heat pump mode. Water will drain from the 
unit at the base. Place the unit so as not to 
create a hazard for pedestrians.
SYSTem oPTionS
• Sea Coast Style Coated Coils / 
Copper-Copper coils
• Wind Baffles - Louvers
inSTaller SuPPlied iTemS
• Power wiring
• Low Volt wiring - 18 AWG minimum
• Secure mounting pad or foundation
• Refrigerant piping 
• Disconnect switch
SiTe PreParaTion
Place the unit on a flat concrete surface or 
pad if on the ground.  Roof mounting should 
use a build up platform. Piping is through 
the wall or roof directly to the unit. In areas 
of heavy snowfall, condensers should be 
set above the level of maximum anticipated 
snowfall (12” is usually adequate).
EMI  offers  the  finest  multi-zone  heat  pump 
outdoor units in the ductless split market, the 
S & T series (S2HB, T2HB, T3HB & T4HB) 
Condensing Units. The S & T series (S2HB, 
T2HB, T3HB & T4HB)  allows the installation of 
two or more circuits from a single outside location 
when space or aesthetic requirements limit the 
use of the number of cabinets outdoors. Each 
zone is independent so no mixing of refrigerant 
occurs.
When  specifying  heat  pump(s),  it  is 
recommended that the matching indoor unit(s) 
be equipped with electric heat. All 9,000, and 
12,000 Btuh circuit units are equipped with the 
Duratec Performance Package which includes 
a  large  capacity  suction  accumulator  with 
surge baffles and enhanced oil management, 
and a factory installed solid core filter drier. All 
18,000 and 24,000 Btuh circuit units include 
a solid core filter drier and high pressure limit 
switch.  The 18,000 Btuh circuits also include a 
large capacity suction accumulator with surge 
baffles and enhanced oil management.
noTe: The crankcase heater is installed 
with 9,000 and 12,000 Btuh heat pumps.
ConTrolS and ComPonenTS
(FACTORY INSTALLED OR SUPPLIED)
deSCriPTion
Thermostatically  controlled  crankcase 
heater
 – This feature energizes the crank-
case  heater  only  when  needed,  removes 
the  heater  from  the  electrical  circuit  at 
conditions  where  it’s  not  required,  saving 
unnecessary Watts, and increasing overall 
system efficiency.