EMI WLH12-S1H2000_101 Manuel D’Utilisation

Page de 4
Rome, New York, USA
Enviromaster International LLC
1
emi 
eNG
iN
ee
R
iNG Submit
tal
 
JOB NAME: _____________________________________  LOCATION: _______________________________________
PURCHASER: _____________________________________________________________________________________ 
ENGINEER: _______________________________________________________________________________________
SUBMITTED TO: _________________________________  FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ]
SUBMITTED BY: _________________________________  DATE:____________________________________________
UNIT DESIGNATION:    SCHEDULE #:  _______________  MODEL #:  ________________________________________ 
WlH12-S1H2000_101
Single-Zone Cooling / Heat Pump
Rev. A [05/08]
WLH12 ELECTRICAL SPECIFICATIONS
V
olts/
HZ/PH
Fan RLA
Heater 
K.W
.
Amps
T
otal 
Amps
Min. V
olt
M.C.A.
HACR 
BRKR
115/60/1
0.64
0.64
104
0.8
15
115/60/1
0.64
.75
6.5
7.14
104
8.9
15
208/230/60/1
0.34
0.34
197
0.4
15
208/230/60/1
0.34
3
13.04
13.38
197
16.7
20
HEAT PUMPS SYSTEM OPTIONS WITH WLH12/S1H2
Cooling 
Btuh 
Heating 
Btuh
SEER  HSPF
SHR
EER
COP
11,400 
10,600
13.0
8.0
 .73
11.5
3.4 
WLH
S1H
CapaCities:
Cooling .................... 11,400 Btuh
Heating (High) ........ 10,600 Btuh
Heating (Low)........... 6,200
 
Btuh
indoor Design temp °F  DB/WB
Cooling .............................. 80/67
Heating.............................. 70/57
Outdoor Design temp °F  DB/WB
Cooling .................................95/75
Heating (High) ......................47/43
Heating (Low).......................17/15
S1H ELECTRICAL SPECIFICATIONS
Model 
Volts/HZ/PH
Total
Amps
Min
Volt
M.C.A.
HACR
BRKR
S1H2A
115/60/1
10
104
12.2
20
S1H2D
208/230/60/1
5.1
197
6.2
15
stanDarD Features:
evaporator – High Wall mounted:
•  Universal  unit  mounted,  infrared  compatible  control
package, configurable to either unit mount or optional
wall thermostat operation.
•  Compatible  with  most  standard  wall  mounted,  24V
thermostats
•  Motorized supply louver
•  Integral field condensate pump connector
•  Condensate pan over flow protection
•  Anti-short cycle compressor protection
•  Indoor coil freeze protection
•  Dry mode for humidity control (optional electric heat 
required)
•  Memory  back  up  for  auto  re-start  following  power
outage
•  Fan purge
stanDarD Features:
Condenser – Side Discharge / vertically arranged:
• R-22 refrigerant
• Factory installed Low Ambient cooling to 32°F
• Duratec compressor protection package
- Suction Accumulator
- Filter dryer
- High pressure switch (manual reset)
- Thermostatically controlled crankcase heater
- Start assist
• Coated wire coils and fan guards
• Five year compressor / one year parts warranty
Thermostatically controlled crankcase heater – This feature 
energizes the crankcase heater only when needed, removes 
the heater from the electrical circuit at conditions where 
it’s not required, saving unnecessary Watts, and increasing 
overall system efficiency.