ICP DAS USA DFS2H324J2A Manuel D’Utilisation

Page de 15
6
ATTACH THE REMOTE CONTROLLER
MOUNTING BRACKET
1. Use the two screws supplied with the controller to attach the
mounting bracket to the wall in the location selected by the
customer (see Fig. 10 ).
2. Install batteries in the remote control.
3. Place remote control into remote control mounting bracket.
4. For remote control operation, refer to the unit Owner's
Manual.
Outdoor Unit Installation
NOTE:  The outdoor unit must be installed on a solid surface
(mounting base).
1. Place the rubber absorption cushions (supplied with the
outdoor unit) under the unit's feets to prevent vibrations.
2. Fasten the outdoor unit legs to the mounting base, as shown
in Fig. 12. The cushion goes between the legs and the
mounting base.
3. Be sure that the unit is leveled.
  MAKE REFRIGERANT PIPING CONNECTIONS (OUTDOOR
UNIT) — To connect the refrigerant lines:
Make sure to properly identify and separate between the pip-
ing and control cables coming from indoor unit No. 1 and the pip-
ing and cables coming from indoor unit No. 2
Use only "L" type sealed, dehydrated copper refrigerant tub-
ing. No other type of tubing may be used. Use of other types of
tubing will void the manufacturer's warranty.
Do not open service valves or remove protective caps from
tubing ends until all the connections are made.
Bend tubing with special bending tools to avoid the forma-
tion of sharp bends. Take care to avoid kinks or flattening of the
tubing.
Keep the tubing free of dirt, sand, moisture, and other con-
taminants to avoid damaging the refrigerant system.
Avoid sags in the suction line to prevent the formation of oil
traps.
Insulate each tube with 3/8-in. walled thermal pipe
insulation. Inserting the tubing into the insulation before making
the connections will save time and improve installation The
suction and mixed-phase lines should never come in direct
contact.
4 ABSORPTION CUSHION TO
BE PUT UNDER EACH LEG
INTER UNIT
TERMINAL BLOCK
N            L1
115 VAC
1
2
3
4
5
24 V
AC
FAN (H)
FAN (L)
R.V.S
COMP.
COMMON
1
2
3
4
5
24 V
AC
FAN (H)
FAN (L)
R.V.S
COMP.
COMMON
1
2
METAL CONDUIT
CONNECTION PLATE
1
2
3
4
5
24 V
AC
FAN (H)
FAN (L)
R.V.S
COMP.
COMMON
TH3 SENSOR
(HEAT PUMP ONLY)
POWER SUPPLY
CABLE
INTER UNIT CABLE
N            L1
115 VAC
1
2
3
4
5
24 V
AC
FAN (H)
FAN (L)
R.V.S
COMP.
COMMON
1
2
3
4
5
24 V
AC
FAN (H)
FAN (L)
R.V.S
COMP.
COMMON
1
2
HIGH/LOW
VOLTAGE METAL
BARRIER
POWER SUPPLY
TERMINAL BLOCK
REMOTE CONTROL
MOUNTING BRACKET
Fig. 10 — Attach Mounting Bracket to the Wall
Fig. 11 —Wall Mounted Unit - RTX
(OPTIONAL)
Fig. 12 — Legs Mounting Base and Wiring
Outdoor Units Models:
DFC2A/H318J2A, DFC2A/H324J2A
REMOTE CONTROL
TURBO-JET
ECONOMY