Danby DPAC7099 Manuel D’Utilisation

Page de 23
7
Power Control 
The Power Control turns the unit on and off
Mode Control 
The Mode Control has 4 settings:
• Cool • Dehumidify • Fan • Auto
The settings are adjusted by the Mode Control button
• Cooling Mode 
During the cooling mode the air is cooled and hot air is exhausted
outside through the exhaust tube. Adjust fan speed and 
temperature to suit your desired comfort level. 
Note: The air exchange hoses must vent outside the room when
using Cool Mode.
• Dehumidify Mode 
Air is dehumidified as it passes through the air conditioner, without
being in full cooling mode. If room temperature is higher than 25°C
(77°F), fan speed can be adjusted; otherwise fan speed is fixed to
low.
Note: If the unit is to be used as a dehumidifier,
do not connect the exhaust hose to vent 
outside. When using as a dehumidifier, 
continuous drainage is necessary.
• Fan Mode 
Air is circulated throughout the room with no
cooling. 
Note: Unit does not need to be vented in Fan
Mode. 
• Auto Mode 
In Auto Mode the unit swill switch its mode and
fan speed automatically based on the ambient
temperature.
Fan Speed Control 
The Fan Speed Control has 4 settings:
• Auto (Cooling only) • High • Medium • Low
Temp. Set Controls 
The temperature can be set by means of the 
and 
buttons on the remote control. The 
temperature can be set between 16°C (61°F)
and 32°C (89°F), and pressing the 
and 
buttons will cause the set temperature to remain
in the display panel for approximately 5 
seconds. The display will then revert back to
showing the current room temperature.
Note: It is only possible to set the temperature
when in Cooling Mode. The temperature cannot
be set when in Auto, Dehumidify, or Fan mode. 
Fahrenheit/Celsius Selector 
Pressing this button will switch the display
between degrees Celsius and degrees
Fahrenheit.
Note: Initial setting is °C
Timer Setting Control 
Press the Timer button on the remote control to
set the timer. The “ON” or “OFF” logos 
(depending on timer modes “A” or “B” below)
will appear in the display panel, the clock 
symbol will flash for approximately 10 
seconds, and the display panel will show the
time of 8 hrs. While the clock symbol is 
flashing, press the and buttons on the remote
control to select the time (in hours, between 00
and 24) for either of the timer modes “A” or “B”
as detailed below. The time selected will be
shown on the display panel and after 
approximately 10 seconds the clock symbol will
remain illuminated together with either the “ON”
or “OFF” logo.
Timer Mode A) Auto Off:
With the machine on and running, set the timer
to select the number of hours you would like the
unit to run until it automatically shuts off. The
set time will be shown in the display together
with the clock symbol and “OFF” logo.
Timer Mode B) Auto On:
Switch the machine on using the ON/OFF
button (either on the machine itself or on the
remote control) so that the machine is running
and the desired mode is selected. Press the
ON/OFF button again to put the machine in
stand-by mode. Set the timer to select the 
number of hours until it is required for the unit
to start up automatically. The set time will be
shown in the 
display together with the clock
symbol and the “ON” logo.
Timer Cancel Control 
If the time has been set as in either “A” or “B”
above and it is then decided that the timer is
not required, pressing the CANCEL button
will turn the timer off. 
REMOTE CONTROL