Friedrich RC/RH 10 Manuel D’Utilisation

Page de 26
15
www.retroaire.com
The Right Fit For Comfort
Front View
Cooling Chassis
Wall Sleeve
1�x1� Foam Tape
RC/RH45 PERFORMANCE DATA*
Unit Size Cooling 
Btuh
EERs
Heat Pump 
Btuh
COP Fresh Air 
CFM
9
9,500
10
8500
2.8
40/35
12
11,900
10
11400
2.9
40/35
15
14,700
9.2
13800
2.8
40/35
18
16,900
9.1
N/A
N/A
40/35
RC/RH45 INSTALLATION INSTRUCTIONS 
(
Continued
)
8. Once confi dent that all seals are the correct size and in 
the proper location and the correct baffl es are attached 
to  the  condenser  coil  in  the  proper  orientation,  slide 
unit into fi nal position and tighten any tie down bolts or 
screws as necessary.
Hydronic Only: Remove the 2-position connector as-
sembly from kit bag supplied with unit (this will have 
2  yellow  wires  attached).  Connect  this  2-position 
connector to the 2-position connection located on the 
bottom of the control box panel. 
To Connect Aquastat: 
A. Remove the black jumper wire located on the bot-
tom panel of the control box (this is also terminated 
with a 2-position connector).
B. Cut the jumper wire in the middle and splice the 
Aquastat to the jumper. 
C. Place the connecter back into original location. 
Refer to wire diagram on the unit for details.
8. Connect line cord. 
9. See Final Inspection and Startup on page 20.
7. 1” x 1” Open cell foam strips  are provided to prevent 
outside air from entering around the chassis to the room 
from the sides and top of the cabinet (Figure D7). Install 
between wall sleeve and cooling chassis. It is impera-
tive to have a solid air seal between wall sleeve and 
chassis. Failure to do so will result in air leakage from 
outdoor to indoor causing system problems i.e. coils 
freezing, short cycling, and constant running of unit. If 
installer is in need of more foam than supplied in kit, 
consult factory.
*Refer to the charts on page 23 for electrical and optional 
electric heat specifi cations.
Figure D7