York R-410A ZH/ZJ/ZR Series Manuel D’Utilisation

Page de 206
528150-YTG-G-1210
46
Johnson Controls Unitary Products
115°F
125°F
2125
77
101.7
9.7
38.8
35.0
25.9
-
-
-
91.0
10.3
34.9
30.1
22.7
-
-
-
72
92.3
9.4
58.1
49.0
39.9
30.8
-
-
82.4
10.0
54.4
45.4
36.5
27.5
-
-
67
82.9
9.1
77.4
63.0
53.9
44.8
35.7
-
73.8
9.7
73.8
59.2
50.2
41.3
32.3
-
62
78.3
8.9
78.3
78.3
62.9
53.8
44.7
35.6
71.2
9.5
71.2
71.2
56.5
47.6
38.6
29.7
2550
77
103.6
9.7
49.8
39.2
28.6
-
-
-
92.7
10.4
48.3
35.8
25.3
-
-
-
72
94.1
9.4
65.3
54.7
44.1
33.5
-
-
83.9
10.1
61.7
51.1
40.5
30.0
-
-
67
84.5
9.2
80.8
70.2
59.6
49.0
38.3
-
75.2
9.7
75.2
66.4
55.8
45.2
34.7
-
62
79.7
9.0
79.7
79.7
69.5
58.9
48.3
37.6
72.4
9.6
72.4
72.4
62.9
52.3
41.7
31.2
57
79.2
9.0
79.2
78.8
68.2
57.6
46.9
36.3
72.9
9.6
72.9
72.3
58.4
47.8
37.2
26.6
2975
77
105.6
9.8
60.8
43.4
31.3
-
-
-
94.3
10.5
61.6
41.6
27.8
-
-
-
72
95.8
9.5
72.5
60.4
48.2
36.1
-
-
85.4
10.2
69.0
56.8
44.6
32.4
-
-
67
86.1
9.2
84.3
77.4
65.2
53.1
40.9
-
76.5
9.8
76.5
73.6
61.4
49.2
37.0
-
62
81.2
9.0
81.2
81.2
76.1
63.9
51.8
39.7
73.7
9.6
73.7
73.7
69.2
57.0
44.9
32.7
57
80.7
9.1
80.7
80.5
74.6
62.5
50.3
38.2
74.2
9.7
74.2
73.9
64.3
52.1
39.9
27.7
3400
77
107.5
9.8
71.8
47.6
34.0
-
-
-
95.9
10.6
74.9
47.3
30.4
-
-
-
72
97.6
9.6
79.7
66.1
52.4
38.7
-
-
86.8
10.2
76.3
62.5
48.7
34.9
-
-
67
87.7
9.3
87.7
84.5
70.9
57.2
43.5
-
77.8
9.9
77.8
77.8
67.0
53.2
39.4
-
62
82.7
9.1
82.7
82.7
82.7
69.0
55.3
41.7
75.0
9.7
75.0
75.0
75.0
61.8
48.0
34.2
57
82.1
9.1
82.1
82.1
81.1
67.4
53.7
40.1
75.4
9.8
75.4
75.4
70.3
56.5
42.6
28.8
3825
72
96.2
9.6
85.3
70.4
55.4
40.5
-
-
83.7
10.3
81.4
66.4
51.4
36.4
-
-
67
86.4
9.3
86.4
84.8
74.9
60.0
45.0
-
74.9
9.9
74.9
74.9
70.8
55.8
40.8
-
62
81.5
9.2
81.5
81.5
81.5
66.5
51.6
36.6
72.3
9.8
72.3
72.3
72.3
57.6
42.6
27.6
57
80.9
9.2
80.9
80.9
80.4
65.5
50.5
35.6
72.8
9.8
72.8
72.8
70.2
55.2
40.2
25.2
4250
72
94.7
9.7
90.9
74.7
58.4
42.2
-
-
80.5
10.3
80.5
70.3
54.1
38.0
-
-
67
85.1
9.4
85.1
85.1
79.0
62.8
46.5
-
72.1
10.0
72.1
72.1
72.1
58.3
42.2
-
62
80.3
9.2
80.3
80.3
80.3
64.1
47.8
31.6
69.7
9.8
69.7
69.7
69.7
53.5
37.3
21.1
57
79.7
9.2
79.7
79.7
79.7
63.5
47.3
31.0
70.2
9.9
70.2
70.2
70.2
54.0
37.8
21.7
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower 
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
ZH102 (8.5 Ton) (Continued)
Air on
Evaporator Coil
Temperature of Air on Condenser Coil
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
CFM
WB
(°F)
Return Dry Bulb (°F)
Return Dry Bulb (°F)
90
85
80
75
70
65
90
85
80
75
70
65