E33 FPI Direct Vent Gas Insert
OPTIONAL 
BRICK PANEL
Optional Brick Panel Set:
Part #    Description 
 
Qty 
 
  
Top (brick) panel 
 
1
 
  Back 
(brick) 
panel 
 
1
 
  Left 
(brick) 
panel 
 
1
 
  Right 
(brick)panel 
 
1
340-043 Top 
bracket 
 
1
340-094 Bottom 
clips 
 
2
511-031  Brick clips 
   
2
Diagram 1
GAS PIPE
PRESSURE TESTING
The appliance must be isolated from the gas 
supply piping system by closing its individual 
manual shut-off valve during any pressure 
testing of the gas supply piping system at 
test pressures equal to or less than 1/2 psig. 
(3.45 kPa).  Disconnect piping from valve at 
pressures over 1/2 psig.
The manifold pressure is controlled by a regu-
lator built into the gas control, and should be 
checked at the pressure test point.
NOTE: To properly check gas pressure, both 
inlet and manifold pressures should 
be checked using the valve pressure 
ports on the valve.
1)  Make sure the valve is in the "OFF" posi-
tion.
2)  Loosen the "IN" and/or "OUT" pressure 
tap(s), turning counterclockwise with a 1/8" 
wide fl at screwdriver.
3)  Attach manometer to "IN" and/or "OUT" 
pressure tap(s) using a 5/16" ID hose.
4)  Light the pilot and turn the valve to "ON" 
position.
5)  The pressure check should be carried out 
with the unit burning and the setting should 
be within the limits specifi ed on the safety 
label.
6)  When fi nished reading manometer, turn 
off the gas valve, disconnect the hose and 
tighten the screw (clockwise) with a 1/8" 
fl at  screwdriver.  Note: Screw should be 
snug, but do not over tighten.
INSTALLATION 
GAS INSERT 
AERATION SYSTEM
The air shutter can be adjusted by moving the 
adjusting wire up or down. The wire is accessed 
through the bottom louver opening. Open the air 
shutter for a blue fl ame or close for a yellower 
fl ame. The burner aeration is factory set but 
may need adjusting due to either the local gas 
supply or altitude. 
Minimum Air Shutter Opening: 
 5/16" 
Natural 
Gas 
 7/16" 
Propane
CAUTION: Carbon will be produced if air 
 
  shutter is closed too much. 
SIT Valve Description
1) Gas 
cock 
knob
2) Manual 
high/low 
adjustment
3) Pilot 
Adjustment
4) Thermocouple 
Connection 
option
5)  Manifold (Outlet) Pressure Tap
6) Inlet 
Pressure 
Tap
1
2
3
4
5
6
IN
OUT
Note:    Any damage due to carboning result-
ing from improperly setting the aera-
tion controls is NOT covered under 
warranty.
Note: Aeration Adjustment should only 
be performed by an authorized FPI 
Installer at the time of installation or 
service.
Installation of Brick Panels:
1)
  Remove top louver and glass door if in-
stalled.
2)  Remove the logs if they are already in
stalled. Note: the grate must be removed in 
order to remove the bottom log. Ensure you 
slide the bottom coal off to the right-hand 
side to avoid chipping.
3)  Unwrap the brick pattern panels from the 
protective wrapping. Handle the panels with 
care as they can break easily.
4)  Remove the two screws from the bottom of 
the baffl e plate. Install the bottom clips onto 
the baffl e plate (refer to Diagram 1).
Bottom Clips
7) Pilot 
Outlet
8)  Main Gas Outlet
9) Alternative 
TC 
Connection 
Point