CB 1200 Pellet Stove 
Correct Flame Size, Yellow/White in Color
Correct
Figure 32.3
Ash Build Up in Firebox
Pellets Back Up
In Feed Tube
Firepot Overfills
Tall, Lazy Flame, Orange in Color
Incorrect
Figure 32.1
Figure 32.2
D. High Ash Fuel Content Maintenance
•  Frequency:  When the ash build-up exceeds more 
than half way up the firepot.
•  By:  Homeowner
1.  Convection Blower Replacement
a.  Use  proper  shut  down  procedures  to  shut  down  the 
appliance and let it completely cool.
b.   The  convection  blower  is  located  at  the  bottom  rear 
of the appliance. If an outside air kit is also installed, 
depending  on  your  particular  installation  you  may  or 
may not have to remove the outside air flange.  If you 
do, remove the 2 screws using a Phillips head screw-
driver.  You do not need to remove the flex pipe from 
the flange.  
c.  Remove  the  lower  rear  screen  by  removing  the  4 
screws securing the screen to the unit. 
d. 
The motor is mounted on a removable bracket.  Remove the 
2 screws just above the motor and the whole assembly will tilt 
down and pull out.
e. 
Disconnect the wires from the blower. The wires coming 
from the wiring harness are white, red and tan and the 
wires coming from the blower are black, white and red.  
The white connects to white, the red to red and black to 
the tan color wire.
E.  Blower Replacement
Figure 32.4
Remove 2 Screws
Remove 4 Screws
Outside Air
Flex Hose
Convection Blower
Poor quality pellet fuel, or lack of maintenance, can create 
conditions that make the firepot fill quickly with ashes and 
clinkers.  
This condition makes the appliance susceptible to overfill-
ing  the  firepot  with  pellets  which  may  result  in  smoking, 
sooting and possible hopper fires.  
Figure 32.1 shows an 
example where the firepot overfills, pellets back up into the 
feed tube and ash has accumulated in the firebox.  
An  inefficient  and  non-economical  method  of  burning  of 
fuel caused by poor quality pellet fuel 
is shown in
 
Figure 
32.2  
The correct flame size when good quality, premium pellet 
fuel is burned is shown in 
Figure 32.3.
If the ash buildup exceeds the half way point in the firepot 
IMMEDIATE ATTENTION AND CLEANING IS REQUIRED.