Quadra-Fire CB1200-B Manuel D’Utilisation

Page de 48
Page  6
7014-082D
September 1, 2008
CB 1200 Pellet Stove 
16.  Snap Disc #1 (Convection Blower) 145°F
Snap disc #1 is located on the right side of the appliance on 
the top of the heat exchanger box.  There are 2 purple wires 
connected to it.  This snap disc turns the convection blower 
on and off as needed.  Power is always present at snap disc 
#1.
17.  Snap Disc #2 (Thermostat Override)  200°F
Snap disc #2 is also located on the right side of the appliance 
between snap disc #1 and convection blower.  There are 2 
yellow wires connected to it.  This snap disc will turn off the 
feed system, which will turn off the appliance if an overfire 
condition should occur or if the convection blower should fail 
to operate.  
18.  Snap Disc #3 (Back Burn Protector) 250°F
Snap disc # is mounted on the back of the auger tube in the 
right side of the appliance just below the feed motor and has 
a red reset button.  To access it remove the feed motor cover 
box from inside the hopper.  If the fire tries to burn back 
into the feed system or push exhaust up the feed tube, this 
snap disc will shut the entire system off.  This disc must be 
manually reset.
19.  Vacuum Switch
The vacuum switch is located on the  left side of the appliance 
behind the inner shield.  This switch turns the feed system on 
when vacuum is present in the firebox. The vacuum switch 
is a safety device to shut off the feed motor if the exhaust 
or the heat exchanger system is dirty or plugged or if the 
firebox door is open. 
20. Wiring Harness
See Figure 36.1 below.
Figure 36.1
Thermocouple
Heat
Output
Switch
Thermostat
Block
Snap
Disc #2
Snap
Disc #1
Feed
Motor
Male
Vacuum
Switch
Capacitor
Female
Convection
Blower
Blower
Speed
Exhaust
Blower
Snap
Disc #
Reset
Button
Call Light
Fuse
Yellow
Yellow
Purple
Purple
Red
Red
Orange
White
White
Yello
w
Blue
Blue
Blue
Black
Black
Gray
Gray
High Temp
High Temp
Yello
w
Igniter