READ AND UNDERSTAND THESE INSTRUCTIONS  
BEFORE INSTALLING LUMINAIRE. 
This luminaire is intended for installation in accordance with the National Electrical Code and local regulations.  
To assure full compliance with local codes and regulations, check with your local electrical inspector before 
installation.  To prevent electric shock, turn off electricity at main power supply before proceeding. 
Retain these instructions for maintenance reference.
INSTALLATION PROCEDURE FOR: LYTECASTER® 2000LVRE1 LOW VOLTAGE REMODELER KIT 
CAUTION: 
USE ONLY WITH REFLECTOR TRIMS PROVIDED BY LIGHTOLIER.  USE OF OTHER MANUFACTURER’S TRIMS MAY VOID THE 
UNDERWRITERS LABORATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD.
 
INSTRUCTION SHEET NO.
IS:2000LVRE1
A0607 
Page 1 of 2 
 COMPANY
631 Airport Road, Fall River, MA 02720 
CAUTION: 
BEFORE INSTALLING FRAME-IN KIT AND REFLECTOR TRIM, READ ALL MARKINGS ON FRAME-IN KIT AND  REFLECTOR TO 
DETERMINE LAMP WATTAGE AND TYPE APPLICABLE FOR YOUR INSTALLATION. 
 
1. CUT OPENING (Fig. A) 
    
Use aperture sticker provided as a template to cut a hole in the ceiling. Cut to 
outside edge of sticker. 
 
     * Lightolier also offers a hole cutter (HC-356) that can be purchased separately to 
assist with quick, clean trim installations. In this case, follow the hole cutting 
directions supplied with HC-356. 
     
     
2. WIRE IN & PUSH THRU 
    
Wire to SUPPLY LEADS. (For Cable, use built in CABLE CLAMP in J-BOX). 
WHITE FIXTURE LEAD to NEUTRAL SUPPLY LEAD. BLACK FIXTURE LEAD to 
HOT SUPPLY LEAD (120V). GREEN AND BARE FIXTURE LEAD WIRE TO 
SUPPLY GROUND. Use wirenuts (local hardware item). Place all electrical 
connections in J-Box. Attach J-BOX cover onto J-BOX. For flexible CONDUIT, use 
90° connector (not supplied) or 3/8” SPRING CONNECTOR (provided). If 3/8” 
SPRING CONNECTOR is used, place J-BOX and TRANSFORMER ASSEMBLY 
onto ceiling, attach CONNECTOR to CONDUIT and push into one of the 7/8” dia. 
knock out holes in J-BOX. Pull J-BOX and TRANSFORMER ASSEMBLY toward 
ceiling opening (as shown in Figure B) and complete wiring. 
3. ATTACH MOUNTING RING (Fig. D) 
Push MOUNTING RING into opening until FLANGE sits against ceiling. 
Slide MOUNTING STRAPS down to trap ceiling thickness and then bend up 
to secure (Fig. E). Make sure “J-BOX” SLOT on REMODELER RING is in a 
position that will ensure enough space above ceiling for J-BOX to sit flat 
against ceiling. 
4. ATTACH J-BOX (Fig. E) 
Insert J-BOX MOUNTING STRAP between the ceiling material and MOUNTING RING and through the 
“J-BOX” SLOT on the MOUNTING RING. Pull the STRAP until the J-BOX PLATE sits flat on the 
ceiling with the feet over the edge of the ceiling thickness. Bend J-BOX PLATE MOUNTING STRAP 
up to secure. Make sure J-BOX PLATE is securely attached to the ceiling and the J-BOX is in the 
shown position.   
5. SNAP-ON (Fig.G) 
                                    
→  
6. PUSH-UP (Fig. H) 
 
SEE SEPARATE 
REFLECTOR TRIM 
INSTRUCTION 
SHEETS 
WARNING: 
(
RISK OF FIRE) 
DO NOT INSTALL INSULATION WITHIN 3” OF FIXTURE SIDES OR WIRING COMPARTMENT, NOR ABOVE 
FIXTURE IN SUCH A MANNER SO AS TO ENTRAP HEAT.