Cooper Lighting ADY071461 Manuel D’Utilisation

Page de 5
Thermal cover
plate
1.  If applicable, replace ceiling tile with fixture secured back into ceiling.  Remove adjacent tile from ceiling to facilitate wiring.
2.  Loosen #10-32 x3/8" Pan head screws and remove electrical cover plate and knock out appropriate hole.
3.  Using conduit fitting and nut, secure conduit to cover plate.
4.  Attach appropriate wires and ensure all connections are properly matched.  If ordered, remove thermal cover plate and wire 
     thermal protector.
5.  Replace cover plates and secure with #10-32 x3/8" Pan head screws.
Warning
:  Before starting any work ensure 
that all sources of power are turned off.  All 
work must meet local/national codes and be 
performed by a certified electrician.  Do not 
mount fixtures vertically. 
Installation Instructions
Vault w/ visor
C-Scroll w/ visor
Roundel w/ visor
These installation instructions are valid with the above Ametrix styles.
4.
5.
Sheet 3 of 5
Large, INDOOR
SRR 
(Semi-Recessed, Remote ballast)
Visor and Non-Visor
ADY071461   REV A(ECN070344)
Wiring the fixture
(both ceiling grid and drywall)
Semi-recessed fixtures shown without thermal protectors
Electrical
cover plate
Conduit nut
(by others)
Conduit fitting
(by others)
Conduit 
(by others)
Safety wire
(by others)
Fixture housing
Securing the fixtures with safety wire
(both ceiling grid and drywall)
1.  After securing fixture housing to ceiling structure using provided brackets, reinforce fixture using safety wire(by others).
2.  Using all four tabs located on corners of fixture housing, tie off fixture to structure using safety wire(by others).