 TROUBLESHOOTING    (cont’d)
SYMPTOM 1. Toilet will not flush and water will not enter toilet bowl.
Condition
Mode Switch in SERVICE position.
Valve Open Limit Switch problem. 
 
Valve Closed Limit Switch problem. 
 
Insufficient vacuum in system. 
 
 
 
Flush valve motor relay failure.
Corrective Action
Return Mode Switch to NORMAL position.
With the flush valve fully open, check the “VALVE OPEN” status light. If 
the light is 
off, then the Valve Open Limit Switch is out of alignment or 
defective, or related wiring is defective.
With flush valve in the fully closed position check the “VALVE CLOSED” 
status light. If the light is 
off, then the Valve Closed Limit Switch is out 
of alignment or defective, or related wiring is defective.
Check the “HI VAC” status light. If the light is 
off, the signal from the vac-
uum switch located on the vacuum generator or vacuum tank is absent 
and preventing the toilet from flushing in the NORMAL mode. Check 
for loss of power to the vacuum generator or vacuum pump. Check for 
loose or defective wiring between the vacuum switch and the toilet.
Replace control module.
ERROR CODE CORRECTIVE PROCEDURES
TOILET OPERATION
Condition
+5V status light is 
off (on far  
right of control module):
+5V status light is 
on:
Corrective Action
•  Check toilet fuse or circuit breaker at DC distribution panel.
•  Check for loose or defective wiring between control module and DC 
distribution panel.
•  Check for reverse polarity of input power to control module.
•  If all of above check OK, replace control module.
•  Input power must be 10 volts or higher.   
•  Check control module for error codes.
•  Check “HI VAC” status light. If light is 
off, vacuum is low, preventing 
the toilet from flushing.
•  Check “HOLD TANK FULL” status light. If light is 
on, black water 
holding tank is full, preventing toilet from flushing.
•  Put Mode Switch in SERVICE position. If flush valve 
opens, go to 
next step. If the flush valve 
does not open, go to Symptom 2.  
•  Put the Mode Switch in NORMAL position and push flush handle 
down while observing “FLUSH” status light. The “FLUSH”  status 
light must come 
on when the handle is pressed and go off when the 
handle is released. If the “FLUSH” status light 
did not follow com-
mands of handle, then flush switch or related wiring is defective.
SYMPTOM 2. Flush valve will not open when the Mode Switch is in the SERVICE position or when 
the flush handle is pushed while in the NORMAL position.
Procedure
Check the voltage output  
to the flush valve motor at  
jack 6, pins 9 and 10 on the  
control module as follows:
Corrective Action
•  Pull the control module out as far as the control cables will allow.  
Locate jack 6 at the bottom of the control module.
•  Remove the purple wire from pin 6.
•  With DC voltmeter test leads across pins 9 and 10, flip the Mode 
Switch between the NORMAL and SERVICE positions. If voltage is 
present for about two seconds in the SERVICE position, the flush 
valve motor or related wiring is defective. If voltage is not present, 
replace the control module.