Dometic 3100 Manuel D’Utilisation

Page de 24
13
 TROUBLESHOOTING    (cont’d)
SYMPTOM 3. Flush valve will not close.
Condition/Procedure
Mode Switch is in SERVICE  
position:
Foreign object prevents the flush 
valve from closing and the safety 
circuit locked flush valve in open 
position:
Check for error code at “DO NOT 
FLUSH” status light.
Check the voltage output to  
the flush valve motor at jack 6,  
pins 9 and 10 on the control  
module as follows:
Corrective Action
•  Return switch to the “Normal” position. 
•  Reset the control circuit by putting the Mode Switch in the SERVICE 
position temporarily, then returning to the NORMAL position. If the 
flush valve 
did not close, go to next step. 
•  If showing error, follow the instructions in the Error Code Corrective 
Procedures section.
•  Pull the control module out as far as the control cables will allow.  
Locate jack 6 at the bottom of the control module.
•  Remove the green wire from pin 5.
•  With DC voltmeter test leads across pins 9 and 10, flip the Mode 
Switch between the SERVICE and NORMAL positions. If voltage is 
present for about two seconds in the NORMAL position, the flush 
valve motor or related wiring is defective.
•  If voltage is not present, replace the control module.
SYMPTOM 4. Water will not enter toilet bowl during a flush and when the flush handle is raised 
in the “Add Water” position.
Procedure
Place the Water Level switch  
in the LOW position. Check  
the “WATER VALVE” status  
light while pressing the flush  
handle down:
Corrective Action
•  If the “WATER VALVE” status light comes on, the water valve filter 
screen may be plugged with debris, or the water valve or its related 
wiring is defective.
•  If the “WATER VALVE” status light remains off, replace the control 
module.
•  If voltage is not present, replace the control module.
SYMPTOM 5. Water will not enter toilet bowl when the flush handle is raised in the “Add Water” 
position. 
Procedure
Flush the toilet, then place 
the Water Level switch in the 
LOW position. Then check  
the “LO LEVEL” status light 
while raising the flush handle:
Corrective Action
•  If the “LO LEVEL” status light comes 
on, replace the control module.
•  If the “LO LEVEL” status light does 
not come on, the flush switch or 
its related wiring is defective.
SYMPTOM 6. Water Level switch has no effect on water level in the “Low” or High” position. 
Corrective Action
•  Replace control module.
SYMPTOM 7. Flush valve will not open when Mode Switch is in the “Service” position but opens 
during a normal flush cycle. 
Corrective Action
•  Replace control module.