Honeywell 25/50ZS Manuel D’Utilisation

Page de 144
Audio Command Center Series Manual — P/N 51889:E1  6/8/2010
67
ACC-FFT Answer Call Push-Button (ACC-25/50ZST)
Operating Instructions
4.3  ACC-FFT Answer Call Push-Button (ACC-25/50ZST)
When a Fire Fighter inserts the FFT Handset (FHS-F) into a remote FFT jack (FPJ-F or RPJ-F), the 
Answer Call LED will flash and the piezo will beep.  Pressing the Answer Call push-button in this 
mode will connect the local FFT Handset with the remote FHS-F.  Conversations between the two 
locations can be performed by pressing the Push-to-Talk switch on each FFT Handset.  To termi-
nate the conversation, unplug the remote FFT Handset (FHS-F) and press the Answer Call push-
button again.  Figure 3.15, “ACC-FFT Fire Fighter Telephone Module” on page 55, for additional 
information.
4.4  LED Indicators
4.4.1  LEDs Visible with Backbox Door Closed (Figure 4.1 on 
Power On
A green LED that remains on while power is within correct limits.  If this indicator fails to light 
under normal conditions, check for AC and battery power and service the system immediately.
System Trouble
This yellow LED turns on steady to indicate that a fault or abnormal condition exists and that the 
ACC-25/50 may be inoperative.  Do not allow trouble conditions to remain on the system.  Service 
the system immediately.
Message Generator Trouble
This yellow LED turns on steady when the supervised digital message generator fails or falls below 
acceptable levels.
Tone Generator Trouble
This yellow LED turns on steady when one of the supervised tone generators fail or fall below 
acceptable levels.
Microphone Trouble
This yellow LED turns on steady when the supervised microphone connection is open.
Record/Playback
This green LED turns on steady, when the Record/Playback push-button is pressed, to indicate that 
the recording process is ready to begin.  The LED remains on during recording and turns off when 
the Record/Playback push-button is pressed to terminate the recording process
Zone 1/All-Call
Dual Zone Operation - this two color LED turns green when Zone 1 speaker circuit is activated 
by an alarm condition or manually and turns yellow when the push-button is pressed during an 
alarm condition to turn off the Zone 1 speaker circuit
Single Zone Operation - this LED turns green when the push-button is pressed to initiate an 
All-Call operation
Zone 2/Audio On/Off
Dual Zone Operation - this two color LED turns green when Zone 2 speaker circuit is activated 
by an alarm condition or manually and turns yellow when the push-button is pressed during an 
alarm condition to turn off the Zone 2 speaker circuit
Single Zone Operation - this two color LED turns green to indicate that audio has been 
activated by an alarm condition or manually and turns yellow when the push-button is pressed 
during an alarm condition to turn off the audio