Emerson Series 3000 MVD Manuel D’Utilisation

Page de 348
Configuration and Use Manual
135
Startup Procedures
Co
nfi
guri
ng Custod
T
ran
sf
er
Star
tup
Con
fig
urin
g Tic
kets
Con
fig
ur
in
g Di
gi
tal
 Co
mm
u
n
ic
a
tio
ns
Co
nfi
guri
ng Custod
T
ran
sf
er
Star
tup
Con
fig
urin
g Tic
kets
Con
fig
ur
in
g Di
gi
tal
 Co
mm
u
n
ic
a
tio
ns
Co
nfi
guri
ng Custod
T
ran
sf
er
Star
tup
Con
fig
urin
g Tic
kets
Con
fig
ur
in
g Di
gi
tal
 Co
mm
u
n
ic
a
tio
ns
Co
nfi
guri
ng Custod
T
ran
sf
er
Star
tup
Con
fig
urin
g Tic
kets
Con
fig
ur
in
g Di
gi
tal
 Co
mm
u
n
ic
a
tio
ns
16.3.1
Zero failure and restoring zero values
If the zero procedure fails, see Section 16.3.4 for troubleshooting information. 
Additionally, if you have the enhanced core processor:
You can restore the factory zero. This procedure returns the zero value to the value obtained at 
the factory, if the factory configuration has been saved on the transmitter.
If you are using ProLink II to zero the flowmeter, you can also restore the prior zero 
immediately after zeroing (e.g., an “undo” function), as long as you have not closed the 
Calibration window or disconnected from the transmitter. Once you have closed the 
Calibration window or disconnected from the transmitter, you can no longer restore the prior 
zero.
16.3.2
Preparing for sensor zero calibration
To prepare the flowmeter for sensor zero:
1. Install the sensor according to the appropriate sensor instruction manual.
2. Apply power to the Series 3000 system, then allow it to warm up for at least 30 minutes.
3. Run the process fluid to be measured through the sensor until the sensor temperature 
approximates the normal process operating temperature.
4. Close the shutoff valve downstream from the sensor.
5. Fill the sensor completely with process fluid under normal process conditions of temperature, 
density, pressure, etc., and ensure zero flow through the sensor.
6. Make sure flow through the sensor is completely stopped.
16.3.3
Performing the sensor zero calibration
To perform the sensor zero:
1. From the Calibration menu (see Figure 16-1), select 
Sensor Zero
. The Calibration menu is 
accessed through the Maintenance option of the Management menu.
2. Check the setting for 
Zero Time
, and change it if desired.
3. Note the value displayed for 
Mass Flow Rate
. If it is non-zero, recheck sensor preparation 
4. Select 
Calibrate Zero
, then press 
SEL
. During sensor zero:
Calibration In Progress
 alarm is generated.
The time remaining counts down to zero seconds.
The 
Calibrate Zero
 screen displays an “In Progress” status, and the zero offset in 
microseconds.
CAUTION
If fluid is flowing through the sensor, the sensor zero calibration may be 
inaccurate, resulting in inaccurate process measurement.
To improve the sensor zero calibration and measurement accuracy, ensure that 
process flow through the sensor has completely stopped.