Emerson Model 1700 Manuel D’Utilisation

Page de 350
8.6
Start and stop totalizers and inventories
Display (standard)
See 
.
Chinese-language
display
Offline Maintain
 > Totalizer Mgmt > Start Totals
Offline Maintain
 > Totalizer Mgmt > Stop Totals
ProLink II
ProLink
 > Totalizer Control > Start
ProLink
 > Totalizer Control > Stop
ProLink III
Device Tools
 > Totalizer Control > Totalizer and Inventories > Start All Totals
Device Tools
 > Totalizer Control > Totalizer and Inventories > Stop All Totals
Field Communicator Service Tools > Variables > Totalizer Control > All Totalizers > Start Totalizers
Service Tools
 > Variables > Totalizer Control > All Totalizers > Stop Totalizers
Overview
When you start a totalizer, it tracks process measurement. In a typical application, its value
increases with flow. When you stop a totalizer, it stops tracking process measurement and
its value does not change with flow. Inventories are started and stopped automatically,
when totalizers are started and stopped.
Important
Totalizers and inventories are started or stopped as a group. When you start any totalizer, all other
totalizers and all inventories are started simultaneously.When you stop any totalizer, all other
totalizers and all inventories are stopped simultaneously. You cannot start or stop inventories
directly.
8.6.1
Start and stop totalizers and inventories using the
display (standard option)
Prerequisites
The Totalizer Start/Stop display function must be enabled.
At least one totalizer must be configured as a display variable.
Procedure
To start all totalizers and inventories using the display:
1. Scroll until the word TOTAL appears in the lower left corner of the display.
Important
Because all totalizers are started or stopped together, it does not matter which total you
use.
2. Select.
3. Scroll until START appears beneath the current totalizer value.
Transmitter operation
Configuration and Use Manual 
129