Emerson 1700 Manuel D’Utilisation

Page de 80
64
Micro Motion
®
 Model 1700 and 2700 Transmitters
Specifications
A.3
Performance specifications
For performance specifications, refer to the sensor specifications.
A.4
Physical specifications
The physical specifications of the transmitter include:
A.4.1
Housing
NEMA 4X (IP67) epoxy painted cast aluminum housing.
Terminal compartment contains output terminals, power terminals and service-port terminals. The 
output terminals are physically separated from the power- and service-port terminals.
The electronics compartment contains all electronics and the standard display.
The sensor compartment contains the wiring terminals for connection to the core processor on 
the sensor.
Screw-terminal on housing for chassis ground.
Cable gland entrances are either 1/2
″–14 NPT or M20 × 1.5 female conduit ports.
A.4.2
Mounting
Model 1700/2700 transmitters are available integrally mounted to some Micro Motion sensors, or in 
two remote-mount configurations.
Remote-mount transmitters include a mounting bracket, and require 4-wire or 9-wire signal 
cables between the sensor and the transmitter. Maximum distance from other flowmeter 
components depends on the installation type and cable type, as described in Table A-2.
The transmitter can be rotated on the sensor or the mounting bracket, up to 360° in
90° increments.
Table A-2
Maximum cable lengths
Cable type
Wire gauge
Maximum length
Micro Motion 9-wire
Not applicable
60 feet (20 meters)
Micro Motion 4-wire
Not applicable
1000 feet (300 meters)
User-supplied 4-wire
• Power wires (VDC)
22 AWG (0,35 mm
2
)
300 feet (90 meters)
20 AWG (0,5 mm
2
)
500 feet (150 meters)
18 AWG (0,8 mm
2
)
1000 feet (300 meters)
• Signal wires (RS-485)
22 AWG (0,35 mm
2
) or larger
1000 feet (300 meters)