Emerson IFT9701 Manuel D’Utilisation

Page de 90
Model IFT9701 Transmitter Instruction Manual
61
Troubleshooting
 continued
Co
nfig
uratio
n wit
Co
mm
u
n
ic
ato
r
T
ro
u
b
lesho
ot
ing
Con
fig
ur
atio
n
 w
ith
 Pr
oL
in
II
Flo
w
meter Star
tup
To check integrity of sensor wiring circuits:
1. Disconnect the transmitter's power supply.
2. Disconnect sensor wiring from the transmitter's intrinsically safe terminal block in the sensor 
wiring compartment. See Figure 8-1.
3. Use a DMM to measure resistance between wire pairs, as indicated in Table 8-4.
4. If the transmitter is remotely mounted from the sensor, repeat the measurements at the 
terminal block in the sensor junction box to distinguish cable failure from sensor failure.
8.6
Over range and sensor failure conditions
If a sensor failure occurs, if the flowmeter cable is faulty, or if flow, temperature, or density goes 
outside the sensor limits, all the following occur:
The transmitter produces fault outputs.
The diagnostic LED blinks ON 4 times per second.
The optional LCD reads “SENS0”.
Table 8-3
Sensor terminal designations
Terminal number
Wire color
Function
1
Brown
Drive +
2
Red
Drive –
3
Orange
Temperature –
4
Yellow
Temperature lead length compensator
5
Green
Left pickoff +
6
Blue
Right pickoff +
7
Violet
Temperature  +
8
Gray
Right pickoff –
9
White
Left pickoff –
Table 8-4
Normal resistance and voltage ranges for flowmeter circuits
Notes
• Temperature sensor value increases 0.38675 ohms per °C increase in temperature.
• Nominal resistance values will vary 40% per 100 °C. However, confirming an open coil or shorted coil is more important 
than any slight deviation from the resistance values presented below.
• Resistance across terminals 6 and 8 (right pickoff) should be within 10% of resistance across terminals 5 and 9 (left 
pickoff).
• Resistance values depend on the sensor model and date of manufacture.
Circuit
Wire colors
Sensor 
terminals
Nominal resistance range
Drive coil
Red to brown
1 to 2
8 to 2650
Ω
Left pickoff
Green to white
5 to 9
15.9 to 300
Ω
Right pickoff
Blue to gray
6 to 8
15.9 to 300
Ω
Temperature sensor
Orange to violet
3 to 7
100
Ω
 at 0°C + 0.38675
Ω
/°C
Lead length compensator
Yellow to violet
4 to 7
100
Ω
 at 0°C + 0.38675
Ω
/°C