for Your InforMatIon
start up condItIons
sMoKe/odor
It is not uncommon to experience a small amount of smoke and odor 
during the initial start-up. This is due to burning off of oil from metal 
parts, and will disappear in a short while.
therMal eXpansIon
As water is heated, it expands (thermal expansion). In a closed 
system, the volume of water will grow. As the volume of water 
grows, there will be a corresponding increase in water pressure 
due  to  thermal  expansion.  Thermal  expansion  can  cause 
premature  tank  failure  (leakage).  This  type  of  failure  is  not 
covered under the limited warranty. Thermal expansion can also 
cause intermittent temperature-pressure relief valve operation: 
water discharged from the valve due to excessive pressure build 
up. The temperature-pressure relief valve is not intended for the 
constant relief of thermal expansion. This condition is not covered 
under the limited warranty.
A  properly-sized  thermal  expansion  tank  should  be  installed 
on all closed systems to control the harmful effects of thermal 
expansion.  Contact a local plumbing service agency to have a 
thermal expansion tank installed.
stranGe sounds
Possible noises due to expansion and contraction of some metal 
parts during periods of heat-up and cool-down do not necessarily 
represent harmful or dangerous conditions.
Condensation causes sizzling and popping within the burner area 
during heating and cooling periods and should be considered normal. 
See “Condensate” in this section.
operatIonal condItIons
sMellY water
In each water heater there is installed at least one anode rod (see 
parts  section)  for  corrosion  protection  of  the  tank.  Certain  water 
conditions  will  cause  a  reaction  between  this  rod  and  the  water. 
The most common complaint associated with the anode rod is one 
of a “rotten egg smell” in the hot water. The smell is a result of four 
factors which must all be present for the odor to develop:
a.  A concentration of sulfate in the supply water.
b.  Little or no dissolved oxygen in the water.
c.  A sulfate reducing bacteria which has accumulated within the 
water heater (this harmless bacteria is nontoxic to humans).
d.  An excess of active hydrogen in the tank. This is caused by the 
corrosion protective action of the anode.
Smelly water may be eliminated or reduced in some water heater models 
by replacing the anode(s) with one of less active material, and then 
chlorinating the water heater tank and all water lines. Contact the local 
water heater supplier or service agency for further information concerning 
an Anode Replacement Kit and this chlorination treatment.
If the smelly water persists after the anode replacement and chlorination 
treatment, we can only suggest that chlorination or aeration of the water 
supply be considered to eliminate the water problem.
do not remove the anode leaving the tank unprotected. By doing 
so, all warranty on the water heater tank is voided.
“aIr” In hot water faucets
HYDROGEN GAS: Hydrogen gas can be produced in a hot water 
system that has not been used for a long period of time (generally 
two  weeks  or  more).  Hydrogen  gas  is  extremely  flammable  and 
explosive. To prevent the possibility of injury under these conditions, 
we  recommend  the  hot  water  faucet,  located  farthest  away,  be 
opened  for  several  minutes  before  any  electrical  appliances 
which are connected to the hot water system are used (such as a 
dishwasher or washing machine). If hydrogen gas is present, there 
will probably be an unusual sound similar to air escaping through the 
pipe as the hot water faucet is opened. There must be no smoking 
or open flame near the faucet at the time it is open.
hIGh water teMperature shut off sYsteM
This water heater is equipped with an automatic gas shut-off system. 
This system works when high water temperatures are present. Turn 
“OFF” the entire gas supply to the water heater. The high temperature 
shut-off is built into the gas control valve. It is non-resettable. If the 
high temperature shut-off activates, the gas control valve must be 
replaced. Contact your gas supplier or service agency.