Empire Comfort Systems DVP42FP3 Manuel D’Utilisation

Page de 52
Page 16
17375-6-0705
MAXIMUM HORIZONTAL
RUN WITH NO VERTICAL
RISE AND 90° ELBOW
MAXIMUM HORIZONTAL
RUN WITH MINIMUM
VERTICAL RISE AND
90° ELBOW
minimum
Figure 25
Figure 24
MINIMUM  HOLE LOCATION DIMENSIONS FOR THROUGH THE 
WALL HORIZONTAL INSTALLATIONS WITH 90 DEGREE ELBOW 
OFF TOP OF FIREPLACE
Positioning the Fireplace
Determine the exact position of the appliance so the direct vent termination 
will be centered (if possible) between two (2) studs. This will avoid any 
extra framing. All vent kit pipes should be assembled on the unit after 
the unit is moved into the final position.
Cutting the Hole (Figures 23)
After the fireplace has been positioned in its permanent location, the hole 
through the exterior wall of the house can be cut. This hole must be 12" 
(305mm) high x 10" (254mm) wide with its center line determined by the 
amount of vertical rise and horizontal run of the termination. (See Figure 
23) When locating the hole it must be noted that the bottom of the cap 
must be 12" (305mm) above the ground level, and top of the cap must 
be no less than 18" (457mm) below a combustible projection, and no 
closer than 9" (229mm) to any wall running parallel to vent termination. 
(See Figure 24)
A
CENTER OF
ELBOW
STRAIGHT
OUT
(MINIMUM)
2
30
FIREPLACE
SERIES
HARD ELBOW DIMENSIONS
"A"
"B"
"C"
DVP42FP
43-1/2"
(1105mm)
5" 
(127mm)
 7" 
(178mm)
DVP48FP
43-1/2"
(1105mm)
5" 
(127mm)
 7"
 (178mm)
FIREPLACE
SERIES
FLEX PIPE 90 DEGREE BEND
"A"
"B"
"C"
DVP42FP
46"
(1143mm)
5" 
(127mm)
 7" 
(178mm)
DVP48FP
46"
(1143mm)
5" 
(127mm)
7"
 (178mm)
Figure 23