Empire Comfort Systems SR-30-3 Manuel D’Utilisation

Page de 48
16942-3-0506
Page 8
SR-6 CLEARANCES
Figure 3 (SR-6)
When facing the front of the appliance the following minimum clearances to combustible construction must be maintained.
Left side 6 inches (152mm). Right side 6 inches 152mm).
Do not install in alcove or closet. 
Rear wall 0 (0mm) inches. Ceiling 24 inches (610mm).
Minimum vertical clearance from a projection above the appliance (shelves, window sills, etc.) 10 inches (254mm).
Maximum horizontal extension of projection above the appliance 12 inches (305mm).
Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).
Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing and proper operation must be provided.
Figure 4 (SR-6)
CEILING
WINDOW SILL OR SHELF
24” MIN
(610mm)
10” MIN
(254mm)
12” MAX
(305mm)
0” (0mm) CLEARANCE
TO REAR WALL
SIDE VIEW
2” MIN
(51mm)
FLOOR