Framing and Finishing 
  1.  Choose unit location.
  2.  Frame in fireplace with a header across the top. It is important 
to allow for finished face when setting the depth of the 
frame.
  3.  Attach fireplace to frame using adjustable frame. Preset 
depth to suit facing material (adjustable to 1/2", 5/8" or 
3/4" depths).
  4.  Use (8) 1/2" hex-head screws supplied in hardware package, 
to screw through slotted holes in drywall strip and then 
screw into pre-drilled holes on fireplace side. Measure from 
face of fireplace to face of drywall strip to determine final 
depth. 
INSTALLATION
Figure 8
Vent Pipe Clearance
Note:  Maintain one inch (1") of clearance around vertical vent 
pipe. See Fig. 9A. For horizontal vent, maintain a minimum 1" 
clearance to the bottom and sides of the vent, and 3" clearance to 
combustibles above the vent pipe. See Fig. 9B
Figure 9A
VENT PIPE
1" MINIMUM CLEARANCE AROUND VENT PIPE
Top of Vent
Combustibles NOT
allowed in shaded
area
1"
1"
3"
(25 mm)
8” Diameter
intake vent
5” Diameter flue
(25 mm)
(76 mm)
Figure 9B