Empire Comfort Systems DVP48FP9 Manuel D’Utilisation

Page de 52
Page 11
17375-6-0705
Note: For finishing to top of fireplace, refer to Figure 12.
DVP42
DVP48
"A" 37 3/4"
37 3/4"
"B" 43 3/8"
49 3/8"
"C" 19 7/8"
19 7/8"
Figure 11
Attention: If a base or mantel is not used and the appliance is 
installed directly on carpeting, tile or other combustible material 
other than wood flooring, it shall be installed on a metal or wood 
panel extending the full width and depth of the appliance. The 
vertical dimension in Figure 11 must be adjusted when a metal or 
wood panel is placed beneath the appliance.
Finishing (Figures 12 and 13)
Finish the walls with the material of your choice. Figure 3 on 
page 7  shows the minimum vertical and corresponding maximum 
horizontal dimensions of mantels or other combustible projections 
above the top front edge of the fireplace.
Only non-combustible materials may be used to cover the black 
fireplace front.
Warning: When finishing the fireplace never obstruct or 
modify the air inlet/outlet louvers in any manner. Provide 
adequate clearances around air openings into the combustion 
chamber.
Caution: If the joints between the finished wall and the fireplace 
surround (top and sides) are sealed, a 300°F minimum sealant 
material must be used. These joints are not required to be sealed. 
Only non-combustible material (using 300°F minimum adhesive 
if needed), can be applied as facing to the fireplace surround.
Flush Mount Mantel Installation (Figure 10)
The fireplace must extend 3/4" beyond finished wall surface when 
using a flush mount mantel. Refer to Figure 10 to locate nailing 
flanges on fireplace sides. Mark and drill two (2) 1/8" holes into 
fireplace side to mount each nailing flange. Use eight (8) 1/2" 
hex-head screws supplied in hardware package to attach nailing 
flanges to fireplace sides.
Figure 10
Framing (Figure 11)
Fireplace framing can be built before or after the fireplace is set 
in  place.  Framing  should  be  positioned  to  accommodate  wall 
covering  and  fireplace  facing  material.  The  fireplace  framing 
should be constructed of 2 x 4 lumber or heavier. The framing 
headers may rest on the fireplace standoffs. Refer to Figure 11 for 
minimum framing dimensions.
CAUTION: MEASURE FIREPLACE DIMENSIONS AND 
VERIFY FRAMING METHODS, AND WALL COVERING 
DETAILS  BEFORE  FRAMING  CONSTRUCTION 
BEGINS.
Framing dimension "A" includes a three inch clearance 
for standoffs on firebox. After installing firebox into 
framing, the finished wall surface must cover the three 
inch opening above the firebox.
INSTALLATION (continued)
NAIL OR OTHER SUITABLE FASTENER