Empire Comfort Systems DVP48FP9 Manuel D’Utilisation

Page de 52
Page 29
17375-6-0705
The OWNER should carefully read and follow these operating 
instructions at all times. Lower the door assembly to view the gas 
controls for the fireplace.  
Initial Lighting
Upon completing the gas line or turning the gas valve on after it 
has been in the “OFF” position, a small amount of air will be in the 
lines. When first lighting the fireplace, it will take a few minutes 
for the lines to purge themselves of this air. Once the purging is 
complete, the fireplace will light and operate satisfactorily.
Subsequent lightings of the appliance will not require such purging 
if the gas valve is not turned to “OFF.”
Pilot Flame (Figure 51)
The  thermopile/thermocouple  (standing  pilot)  tips  should  be 
covered with flame. 
Figure 51
750 Millivolt System
The standing pilot (750 millivolt system) is a continuous burning 
pilot. The pilot remains ON even when the main burner is OFF.
When you ignite the pilot, the thermocouple produces millivolts 
(electrical current) which energizes the magnet in the gas valve. 
After 30 seconds to 1 minute time period you can release the gas 
control knob and the pilot will stay ON. Allow your pilot flame to 
operate an additional one (1) to two (2) minutes before you turn the 
gas control knob from the PILOT position to the ON position. This 
time period allows the millivolts (electrical current) to build-up to 
a sufficient level allowing the gas control to operate properly.
1.  Follow the SAFETY and LIGHTING INSTRUCTIONS for 
standing pilot controls found in this manual and on labels found 
in control compartment behind the door assembly.
CAUTION:  During  the  initial  purging  and  subsequent 
lightings, never allow the gas valve control knob to remain 
depressed in the “pilot” position without pushing the piezo 
ignitor button at least once every second. 
2.  During the operating season, leave the control valve knob in 
the “ON” position. This will allow the pilot flame to remain lit. 
Turn the burner flame on or off with the fireplace REMOTE/
OFF/ON switch, wall switch or remote controls.
NOTE: The gas control valve allows you to increase or decrease 
the  height  of  the  main  burner  flame.  The  control  valve  has  a 
pressure regulator with a knob as shown in Figure 50. Rotate 
the  knob  clockwise  to  “HI”  to  increase  the  flame  height  and 
counterclockwise to “LO” to decrease the flame height.
3.  When the operating season is over, turn the REMOTE/OFF/ON 
switch to “OFF” and the control valve to “OFF”. The system, 
including the pilot light, will be shut down.
Figure 50
OPERATING INSTRUCTIONS
CONTROL KNOB
HI/LO REGULATOR