Emerson 308014EN Manuel D’Utilisation

Page de 166
Rosemount Tank Radar REX
Chapter 10 Mechanical Installation
10-44
Installation Manual
308014EN, Edition 4
May 2013
5
Place customer supplied gas-
ket on the Mounting Flange. 
Carefully fit the Pipe Cone into 
the still pipe and tighten the 
Closing onto the Mounting 
Flange (customer supplied 
screws and nuts). Direct the 
Closing so that the marking 
hole aligns with the notch or 
mark on the pipe flange.
6
The tank is now sealed and 
can, as far as Rosemount Tank 
Gauging equipment is con-
cerned, be pressurized.
7
Put the Transmitter Head 
upside down on a flat surface 
and fit the Waveguide Unit into 
the base.
8
Fit the Housing to the Trans-
mitter Head. Carefully check 
that the Guide Pins enter the 
corresponding holes and turn 
the lever of the Waveguide Unit 
so that it fits into the corre-
sponding recess in the Hous-
ing. Tighten the Housing to the 
base of the Transmitter Head 
using four M10 screws and 
washers.
3960_Install_2.eps
Closing
Mounting 
Flange
Notch 
indicating the 
direction of the 
Reference Pin
Marking 
hole
Align!
Reference pin
3960_Install_3.eps
Waveguide Unit
Transmitter 
Head
3960_Install_4.eps
Housing
Guide pins
Waveguide Unit
4 M10 screws 
and washers
Lever