Emerson 308014EN Manuel D’Utilisation

Page de 166
Rosemount Tank Radar REX
Chapter 10 Mechanical Installation
10-16
Installation Manual
308014EN, Edition 4
May 2013
7
Place the TRL/2 adapter on top 
of the antenna feeder.
8
Place the level on top of the 
TRL/2 adapter and adjust the 
antenna to an inclination of 
1.5° towards the center of the 
tank.
Note!
Make sure the air bubble 
touches, but doesn´t 
overlap the 1.5° mark.
TRL/2 Adapter
12.7.eps
0,
0,
1,
1,
,
,
0
0
1
1
3
3
Guide pins
Finger Nut
12.8.eps
Plumb line
Tank center
Incline 1.5° 
towards the 
tank center
Parabola_Inclination.eps