Emerson 308014EN Manuel D’Utilisation

Page de 166
Rosemount Tank Radar REX
Chapter 10 Mechanical Installation
10-18
Installation Manual
308014EN, Edition 4
May 2013
11 Carefully mount the Transmit-
ter Head onto the TRL/2 
adapter. Make sure that the 
guide pins on the TRL/2 
adapter fits into the holes on 
the base of the transmitter 
head. 
Tighten the 4 screws.
12 Remove the Weather Protec-
tion Hood and place the level 
on top of the Transmitter Head 
to check that the inclination of 
the Gauge still is 1.5° towards 
the tank center. If not, loosen 
the finger nut and adjust the 
transmitter.
Note: For bitumen tanks, the 
gauge should be mounted with 
0° inclination.
x4
12.10.eps
Guide pin
Guide pin
0,
0,
1,
1,
,
,
0
0
1
1
3
3
12.1
1.eps
Finger Nut