Wired Remote Temperature Sensing
One remote temperature sensor can be installed indoor or 
outdoor and connected to the thermostat by a maximum 
cable length of 100 meters (300 ft) . Three terminals, +, S & - 
are provided on the terminal block to connect to the White-
Rodgers standard wired remote sensor . This sensor will be 
read by the thermostat only when 24VAC is present . 
When used as indoor sensor, the readings can be weighted 
with the local sensor for specific program periods. User can 
enable or disable the remote sensor in the installer configura-
tion mode and also the outdoor temperature can be selected 
to show on the display .
Once in the installer configuration mode, momentarily press 
the   or   touch key until display indicates 
Remote (at the
top left of the LCD) and OFF (default – in clock digits) .
Pressing   or   touch key will toggle the operation and 
display from 
Remote OFF to Remote On .
When 
Remote On is selected, press   key for the display to 
indicate Remote In (for indoor remote) .
The   or   keys will toggle the operation and display from 
Remote In to Outdoor Remote .
When any remote is selected the temperature will display in 
the clock digits for one second alternating with the current 
time for three seconds when in 
Run Schedule mode .
Outdoor Remote will indicate at the top left of display for 
outdoor remote reading . 
Only
 Remote will show at top left for indoor remote reading .
(
o
F or 
o
C will not indicate with remote temperature readings) . 
Sensing Range: 
Outdoor temperature range is -40 to 140
o
Indoor temperature range is 32
 o
F to 99
 o
F
Weight of Remote Reading:
When in view schedule mode the weight of the indoor remote 
sensor will be shown in the left actual temperature digits des-
ignated as A2 (default for average weight), H4 (high weight) 
or L1 (low weight) . The period (Morning, Day, Evening, Night) 
will also be shown to the right of the weight value in the actual 
temperature digits .
When in view schedule mode, press   and   keys at the
the same time to sequence the indoor remote temperature 
sensor weight from A2 to H4 to L1 and back to A2 for each 
of the program period times for each day . (The H4 weight is 
twice the weight of A2 and A2 is twice the weight of L1) .
When 
Remote In is selected (with Remote selected to On),
press   key for the display to indicate the status of the local 
sensor 
LS On (default for thermostat local sensor operation-
al) . The   and   keys will toggle the function and display 
from 
LS (shown in actual temperature digits) and On (shown 
in clock digits) to
 LS OFF to designate the local sensor is 
disabled .
The local sensor may be disabled only if the indoor remote 
sensor is enabled and functional .
If the indoor remote sensor is disabled or not functional, the 
local sensor will automatically enable and display in the run 
schedule mode .
The actual temperature displayed in the run mode is the 
mathematical weighted sum of the two temperature sensors – 
local and indoor remote . 
(Outdoor remote sensor is not used for this computation) .
If the remote sensor is absent or not enabled then the actual 
temperature will be as measured by the local sensor .
 
 PROGRAMMING