TROUBLESHOOTING 
Reset Operation 
Note: When thermostat is reset, installer configuration menu settings and programming will reset to factory settings. 
If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, you can reset the thermostat by removing 
the wires from terminals R and C (do not short them together) and removing batteries for 2 minutes . After resetting the thermostat, replace the 
wires and batteries . If the thermostat has been reset and still does not function correctly contact your heating/cooling service person or place 
of purchase .  
White-Rodgers is a business 
of Emerson Electric Co.
The Emerson logo is a  
trademark and service mark 
of Emerson Electric Co.
Symptom
Possible Cause
Corrective Action
No Heat/No Cool/No Fan 
(common problems)
1 . Blown fuse or tripped circuit breaker . 
2 . Furnace power switch to OFF . 
3 . Furnace blower compartment door or 
  panel loose or not properly installed . 
4 . Loose connection to thermostat or system .
Replace fuse or reset breaker . 
Turn switch to ON . 
Replace door panel in proper position to engage 
safety interlock or door switch . 
Tighten connections .
No Heat
1 . Pilot light not lit . 
2 . Furnace Lock-Out Condition . Heat 
  may also be intermittent . 
 
 
3 . Heating system requires service or 
  thermostat requires replacement .
Re-light pilot . 
Many furnaces have safety devices that shut down 
when a lock-out condition occurs . If the heat works 
intermittently contact the furnace manufacturer or 
local HVAC service person for assistance . 
Diagnostic: Set SYSTEM Switch to HEAT and 
raise the setpoint above room temperature . Within 
a few seconds the thermostat should make a soft 
click sound . This sound usually indicates the ther-
mostat is operating properly . If the thermostat does 
not click, try the reset operation listed above . If the 
thermostat does not click after being reset contact 
your heating and cooling service person or place of 
purchase for a replacement . If the thermostat clicks, 
contact the furnace manufacturer or a HVAC service 
person to verify the heating is operating correctly .
No Cool
1 . Cooling system requires service or 
  thermostat requires replacement .
Same as diagnostic for No Heat condition except 
set the thermostat to 
COOL and lower the setpoint 
below the room temperature . There may be up to 
a five minute delay before the thermostat clicks in 
Cooling .
Heat, Cool or Fan 
Runs Constantly 
1 . Possible short in wiring . 
2 . Possible short in thermostat . 
3 . Possible short in heat/cool/fan system . 
4 . FAN Switch set to Fan 
ON . 
Check each wire connection to verify they are not 
shorted or touching together . No bare wire should 
stick out from under terminal block . Try resetting 
the thermostat as described above . If the condition 
persists the manufacturer of your system or service 
person can instruct you on how to test the Heat/
Cool system for correct operation . If the system 
operates correctly, replace the thermostat .
Thermostat Setting & 
Thermostat Thermometer 
Disagree
1 . Thermostat thermometer setting 
  requires adjustment .
The thermometer can be adjusted +/- 4 degrees . 
See Temperature Display Adjustment in the Con-
figuration Menu section.
Furnace (Air Conditioner) 
Cycles Too Fast or Too Slow 
(narrow or wide  
temperature swing) 
1 . The location of the thermostat and/or 
  the size of the Heating System may 
  be influencing the cycle rate. 
Digital thermostats provide precise control and 
cycle faster than older mechanical models . The 
system turns on and off more frequently but runs for 
a shorter time so there is no increase in energy use . 
If you would like an increased cycle time, choose 
SL for slow cycle in the Configuration menu, step 7 
(heat) or 8 (cool) . If an acceptable cycle rate is not 
achieved, contact a local HVAC service person for 
additional suggestions .
Forgot Keypad 
Lockout Code
Press the menu button (button will disappear) and 
hold in for 20 seconds . This unlocks the thermostat .
First item in Configuration 
Menu is not SS1 or HP1
Earlier model of thermostat refer to 37-6814D .