9    Specifications 
9-1 
  Standard Specifications  
 1) Three-phase 230V input 
Item 
Specifications 
Drive HP 
1/8 
1/4 
1/2 
Nominal applied motor  
              *1 (HP) 
1/8 
1/4 
1/2 
Rated output  
 capacity *2 (kVA) 
0.28  
0.56  
1.0  
1.6  
2.8  
4.0  
6.6  
Voltage(V) 
3-phase, 200V/50Hz, 200, 220, 230V/60Hz  (Proportional to input voltage) 
Rated current (A) 
0.7 
1.4 
2.5 
4.0 
7.0 
10.0 
16.5 
Overload capacity 
 150% of rated current for 1 min. 
Output ratings
 
Rated frequency (Hz) 
 50, 60Hz 
Phases, Voltage, Fre-
quency 
 3-phase   200 to 230V  50/60Hz 
Voltage/frequency 
variations 
 Voltage: +10% to –15%  
                (Imbalance rate in power supply voltage: 2% or less *7)  
 Frequency: +5% to –5% 
Capability for voltage 
dip *3 
 When the input voltage drops 165V or more, the drive can be operated continuously. 
When the input voltage drops below 165V from rated voltage, the drive can be operated 
for 15ms. 
0.59 
0.94 
1.6 
3.1 
5.7 
8.3 
14.0 
Rated input current *6
 
(with DCR) 
(without DCR) 
1.1 
1.8 
3.4 
6.4 
11.1 
16.1 
25.5 
Input power supply
 
Required power sup-
ply capacity *4 (kVA) 
0.3 
0.4  
0.6 
1.1 
2.0 
2.9 
4.9 
Braking torque 
           *5 (%) 
150 
100 
50 
30 
Braking
 
DC injection  
braking 
 Starting frequency: 3Hz(fixed),  Braking current (0 to 100%), 
Braking   current ( 0 to 30%) 
Protective structure 
(IEC60529) 
• Closed type IP20 
Cooling method 
• Self-cooling 
• Fan cooling 
Weight (Lb)
          
 
1.3 
1.3 
1.5 
1.8 
3.3 
3.3 
4.9