  Common specifications  
 
Item 
Specifications 
Remarks 
Maximum 
output fre-
quency 
 50 to 120Hz (in 1Hz steps) 
 
Base  
frequency 
 25 to 120Hz (in 1Hz steps) 
 
Starting fre-
quency 
 1 to 6Hz (in 1Hz steps) 
 
Setting
 
Carrier fre-
quency 
 0.75 to 15kHz  
 (Vector-distribution PWM control selectable at 7kHz or less) 
When operating at a carrie r frequency of 9kHz or above, the frequency 
may automatically drop to 8kHz to protect the drive. 
 
Accuracy 
 Analog setting:
±
1.0% of maximum frequency (at 25
±
10°C) 
 Keypad panel setting:
±
0.01% of maximum frequency  
                                       (at –10 to +50°C) 
 
Output frequency
 
Setting reso-
lution 
 Analog setting: 1/256 of Maximum frequency  
 Keypad panel setting: 0.1Hz(99.9Hz or less), 1Hz(100Hz or more) 
 
Voltage/
freq. 
 Characteristic
 
 Output voltage proportional to input voltage.  Base frequency  
  adjustable from 25  to 120Hz. 
 
Torque boost 
 Manual setting by code 0 to 31. 
                   (setting for variable torque load available) 
 
Starting torque 
 150% or more (at 6Hz) 
 
Control method 
 Sinusoidal PWM control  
(with simplified current-vibration suppression) 
 
Operation 
method 
 Keypad operation:  RUN  or  STOP  key : 
 
Input signal: Forward/Reverse/Stop command, Coast-to-stop  
              command, Trip command (External alarm),  
              Alarm reset 
 
Frequency set-
ting 
 
 (Multistep) 
 
(Linked opera-
tion) 
 Keypad operation: ,Digital setting by 
 or 
 key 
 Built-in potentiometer 
 Analog input: 0 to +5Vdc, 0 to +10Vdc, 4 to 20mAdc 
 Up to 4 multistep frequencies can be set in 2-bit external signal by terminal 
function selection 
 Setting by RS485 serial communication (Option) 
 
Acceleration/ 
deceleration 
time 
 0.01 to 60.0s  
(Independently adjustable acceleration and deceleration) 
 
Frequency 
limiter
 
 High and low limits can be set for output frequency between 0 to 100% in 
Hz 
 
Bias frequency
 
 The bias frequency can be set from –100 to +100% in Hz. 
 
Control
 
Gain (frequency 
setting signal) 
 5Vdc or 10Vdc gain can be selected.