Wayne WSS30 Manuel D’Utilisation

Page de 36
3
WSS10, WSS20, WSS30
www.waynepumps.com
 
If cables are 
  reversed, damage to 
the control box or battery could result 
and will void the warranty.
5.  
Place battery box within six feet of 
the sump and a 115 VAC separately 
fused outlet. The outlet must 
be protected by a ground fault 
circuit interrupter (GFCI). The area 
must also be clean, dry and well-
ventilated.
6.  
Plug the fl oat switch, pump and 
charger into the control box. The 
connections are marked on the 
control box.
Grounded 
Outlet
Discharge pipe
Inlet pipe
Cap Switch
ON @ 8 inches
 OFF @ approx. 3 inches
12 inch 
Diameter 
min.
Figure 1 (b)
7.  Protect electrical cord from sharp 
objects, hot surfaces, oil and 
chemicals. Avoid kinking the 
cord and replace damaged cords 
immediately.
8.  A sump pit cover must be installed 
to prevent debris from clogging or 
damaging the pump.
  Operation - Primary Pump
 Always 
disconnect the power source 
before attempting to install, 
service, relocate or maintain 
the pump. Never touch sump 
pump, pump motor, water or discharge 
piping when pump is connected to 
electrical power. Never handle a pump 
or pump motor with wet hands or when 
standing on wet or damp surface or in 
water. Fatal electrical shock could occur.
1.  A ground fault circuit interrupter 
(GFCI) is required (see Figure 2).
 Risk 
of 
electrical shock! This pump 
is supplied with a grounding 
conductor and grounding 
type attachment plug. Use a 
grounded receptacle to reduce the risk 
of fatal electrical shock.
Never cut off the round grounding 
prong. Cutting the cord or plug will 
void the warranty and make the pump 
inoperable.
2.  The primary pump is only for use 
on 120 volt (single phase), 60 hz,
15 amp service and is equipped 
with a 3-conductor cord and 
3-prong, grounding type plug.  
Insert the switch cord plug directly 
into a 120-volt outlet.
3.  Insert the pump power cord plug 
directly into the back of the water 
sensor cord plug.
4.  Fill sump with water. The pump will 
start automatically when the water 
is about 1-1/2 inches from the top 
of the switch. The pump will recycle 
thereafter as required.
•  Sump pump will run a minimum 
of 4 seconds, to a maximum of 
16 before stopping.
•  Sump pump run time will be 
determined by the sump pit size 
and water fl ow rate into the 
sump pit.
• Under fl ooding conditions, 
the sump pump will stop for 1 
second, every 16 seconds, and 
automatically turn back on.
5.  Do not operate the pump unless it 
is submerged in water. Dry running  
causes pump failure.
Figure 2
Installation (continued)
24 inch min.
15 inch 
Diameter 
min.
Grounded 
Outlet
Check valve 
(not shown)
Grounded 
Outlet
Grounded 
Outlet
Discharge pipe
24 inch min.
Cap Switch
ON @ 8 inches
 OFF @ approx. 3 inches
Check valve
Inlet pipe
Figure 1 (c)
WSS20
WSS30