The typical installations shown in Figs. 2-4 are only 
guides for selecting and installing system compo-
nents. Contact your Graco distributor for assistance 
in planning a system to suit your needs.
Always use genuine Graco parts and accessories.
Reference numbers and letters in parentheses refer 
to the callouts in the figures and the parts lists on 
pages 28-30, 36-38, and 44-46.
Tightening Clamps Before First Use
After you unpack the pump, and before you use it for the 
first time, check all clamps, and tighten as necessary.
Grounding
To reduce the risk of static sparking, ground the pump 
and all other equipment used or located in the pumping 
area. Check your local electrical code for detailed 
grounding instructions for your area and type of equip-
ment.
Pump: Connect a ground wire and clamp as shown 
in Fig. 1. Loosen the grounding screw (W). Insert 
one end of a 12 ga (1.5 mm²) minimum ground wire 
(Y) behind the grounding screw and tighten the 
screw securely. Connect the clamp end of the 
ground wire to a true earth ground. Order Part No. 
222011 Ground Wire and Clamp.
F
IG
. 1
Fluid hoses: Use only grounded hoses with a maxi-
mum of 500 ft. (150 m) combined hose length to 
ensure grounding continuity.
Air compressor: Follow the manufacturer’s recom-
mendations.
All solvent pails used when flushing: Follow the local 
code. Use only metal pails, which are conductive. 
Do not place the pail on a non-conductive surface, 
such as paper or cardboard, which interrupts the 
grounding continuity.
Fluid supply container: Follow the local code.
The pump is very heavy (see Technical Data on pages 
32, 40, and 48 for specific weights). If the pump must 
be moved, follow the pressure relief procedure on 
page 11 and have two people to lift the pump by grasp-
ing the outlet manifold securely or use appropriate lift-
ing equipment.
Read the TOXIC FLUID OR FUMES HAZARD warn-
ings on page 5.
Read the BURN HAZARD warnings on page 4. To 
reduce the risk of serious injury due to burns, insulate 
and/or label the pump before pumping fluids above 
110°F (43°C).
Read the FIRE AND EXPLOSION HAZARD warnings 
on page 4.
  
"