Earthquake Sound P10 Manuel D’Utilisation

Page de 16
(6) Auto ON/OFF
(10) Sub Operation Switch
When the main “POWER” ON/OFF switch is in the 
In LFE position, the Frequency adjustment becomes 
“OFF” position, this switch has no affect on the 
disabled and the subwoofer runs in a Full range 
subwoofer. When the main “POWER ON/OFF” switch 
mode, from 20Hz - 2kHz. 
is in the “ON” position, this switch allows the auto 
circuit to be engaged. When this switch is in the 
While in Sub position the subwoofer reverts to the 
“AUTO” position, the subwoofer will automatically turn 
manual frequency adjustment, allowing the user to 
“on” when it senses a signal. It will automatically turn 
operate and fine tune the subwoofer to their personal 
“off” after 20 minutes with no signal. When this switch 
taste.
is in the “ON” position, the subwoofer will remain on 
as long as the “POWER” ON/OFF switch is in the 
(11) 50Hz - 160Hz Frequency Adjustment
“ON” position.
This controls the high frequency cutoff point. With the 
control set to the middle, the subwoofer will reproduce 
(7) 110-120V AC Power Connection 
frequencies up to 105Hz. If the control is set fully 
The Earthquake MiniMe is equipped with a built in 
clockwise, the crossover is bypassed and the 
standard, two-prong power connection.
subwoofer will reproduce a wide frequency range. 
With the control fully counter-closkcwise the 
(8) Power Status LED
subwoofer reproduces a narrow range, up to 50Hz.
Earthquake powered subwoofers have an LED on the 
panel that indicates the status of the built-in amplifier. 
Rotate the control until the bass sound natural. If the 
The LED will light red when the amplifier is in standby 
mid-bass sounds natural but you want more low bass, 
mode and green when the amplifier is on and 
turn the control down a little.
receiving a signal.
(12) Volume Control
(9) 0-180° Phase Shift
Manual volume control to regulate your subwoofers 
This control is used to acoustically match the 
power output, to prevent clipping and distortions 
subwoofer’s output to your main speakers. Select the 
caused by overpowering.
position, either 0° or 180°, in which your subwoofer 
has more output at the listening position.
 
inspecting or changing the fuse. Never 
use a fuse with a larger current rating 
than recommended.
Always unplug the power cord before
Earthquake • MiniMe User Manual
6
Control Panel Overview Continued