Mitsubishi Electronics MR-J3 Manuel D’Utilisation

Page de 668
 
 
5 -  40 
5. OPERATION 
 
(2) Timing chart 
6ms or more
Parameter No.PC35
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
(Note 3) Parameter No.PC10
Parameter No.PC35
0
ON
OFF
Rough match (RYn2)
Servo motor speed
Forward rotation start (RYn1)
Automatic/manual selection 
(RYn6)
Limiting torque (RYn4)
Torque limit value
Reverse rotation start (RYn2)
0r/min
Forward 
rotation
Selected point table No.
3ms or less
Stopper
(Note 1)
4ms or more
(Note 2)
Point table No.1 
acceleration time constant
Home position return speed 
parameter No.PC04
Stopper time
parameter No.PC09
Home position address 
parameter No.PC07
Movement completion (RXnC)
Home position return 
completion (RXn3/ZP)
 
Note 1. Configure a sequence that changes the point table selection earlier, considering the delay time of CC-Link communication. 
2. Turns ON when the torque reaches the value set to Forward rotation torque limit (parameter No.PA11), Reverse rotation 
torque limit (parameter No.PA12) or Internal torque limit (parameter No.PC35). 
3. The torque limit that is enabled at this point is as follows. 
 
(Note)  
Internal torque 
limit selection 
(RY(n 2)6) 
Limit value status 
Torque limit to be 
enabled 
0  
Parameter 
No.PC10 
Parameter No.PC35 
Parameter No.PC10 
Parameter No.PC10 
Parameter No.PC35 
Parameter No.PC10 
Parameter No.PC35 
Note. 0: OFF 
1: ON 
 
 
 
 
The parameter No.PC07 (home position return position data) setting value is the positioning address after 
the home position return is completed.