Mitsubishi Electronics MR-J3 Manuel D’Utilisation

Page de 668
 
 
5 -  41 
5. OPERATION 
 
5.6.6 Home position ignorance (servo-on position defined as home position) 
The position where servo is switched on is defined as a home position. 
 
POINT 
 
When executing this home position return, changing to the home position 
return mode is not necessary. 
 
(1) Devices, parameter 
Set the input devices and parameter as follows. 
 
Item Device/Parameter 
used 
Description 
Home position ignorance 
Parameter No.PC02 
4 : Home position ignorance is selected. 
Home position return position data  Parameter No.PC07 
Set the current position at home position return 
completion. 
 
(2) Timing chart 
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
0r/min
Rough match (RXn2)
Servo motor speed
Ready (RD)
Servo-on (RYn0)
Home position address 
parameter No.PC07
Movement completion 
(RXnC)
Home position return 
completion (RXn3/ZP)
 
The parameter No.PC07 (home position return position data) setting value is the positioning address after 
the home position return is completed.