6. PARAMETERS 
 
No.  Symbol 
Name and function 
Initial value 
Unit 
Setting 
range 
PB02  VRFT  Vibration suppression control tuning mode (Advanced vibration suppression 
control) 
The vibration suppression is valid when the parameter No.PA08 (auto tuning) 
setting is "       2" or "       3". When PA08 is "       1", vibration 
suppression is always invalid. 
Select the setting method for vibration suppression control tuning. Setting this 
parameter to "       1" (vibration suppression control tuning mode) 
automatically changes the vibration suppression control - vibration frequency 
(parameter No.PB19) and vibration suppression control - resonance frequency 
(parameter No.PB20) after positioning is done the predetermined number of 
times. 
Droop pulse
Command
Automatic 
adjustment
Droop pulse
Command
Machine side 
position
Machine side 
position
 
Vibration suppression control tuning mode
0 0 0
 
0000h 
  
Setting 
Vibration suppression 
control tuning mode 
Automatically set 
parameter 
 
 
   0 
Vibration suppression 
control OFF 
(Note)   
   1 
Vibration suppression 
control tuning mode 
(Advanced vibration 
suppression control) 
Parameter No.PB19 
Parameter No.PB20 
 
 
   2 
Manual 
mode 
 
 
 
 
 
Note. Parameter No.PB19 and PB20 are fixed to the initial values. 
 
When this parameter is set to "       1", the tuning is completed after 
positioning is done the predetermined number or times for the predetermined 
period of time, and the setting changes to "       2". When the vibration 
suppression control tuning is not necessary, the setting changes to "       0". 
When this parameter is set to "       0", the initial values are set to the 
vibration suppression control - vibration frequency and vibration suppression 
control - resonance frequency. However, this does not occur when the servo off.
 
 
 
PB03 
 
For manufacturer setting 
Do not change this value by any means. 
0000h  
 
PB04 FFC Feed 
forward 
gain 
Set the feed forward gain. When the setting is 100%, the droop pulses during 
operation at constant speed are nearly zero. However, sudden 
acceleration/deceleration will increase the overshoot. As a guideline, when the 
feed forward gain setting is 100%, set 1s or more as the 
acceleration/deceleration time constant up to the rated speed. 
0 % 0 
to 
100