Mitsubishi Electronics MR-J3 Manuel D’Utilisation

Page de 668
 
 
14 -  47 
14. OPTIONS AND AUXILIARY EQUIPMENT 
 
The following table lists the restrictions. 
 
FR-CV-  
Item 
7.5K 11K 15K 22K 30K 37K 55K 
Maximum number of connected servo amplifiers 
Total of connectable servo amplifier capacities [kW] 
3.75 
5.5 
7.5 
11 
15 
18.5 
27.5 
Total of connectable servo motor rated currents [A] 
33 
46 
61 
90 
115 
145 
215 
Maximum servo amplifier capacity [kW] 
3.5 
11 
15 
15 
22 
 
FR-CV-H  
Item 
22K 30K 37K 55K 
Maximum number of connected servo amplifiers 
Total of connectable servo amplifier capacities [kW] 
11 
15 
18.5 
27.5 
Total of connectable servo motor rated currents [A] 
90 
115 
145 
215 
Maximum servo amplifier capacity [kW] 
11 
15 
15 
22 
 
When using the FR-CV-(H), always install the dedicated stand-alone reactor (FR-CVL-(H)). 
 
Power regeneration common converter 
Dedicated stand-alone reactor 
FR-CV-7.5K(-AT) FR-CVL-7.5K 
FR-CV-11 K(-AT) 
FR-CVL-11K 
FR-CV-15K(-AT) FR-CVL-15K 
FR-CV-22K(-AT) FR-CVL-22K 
FR-CV-30K(-AT) FR-CVL-30K 
FR-CV-37K FR-CVL-37K 
FR-CV-55K FR-CVL-55K 
FR-CV-H22K(-AT) FR-CVL-H22K 
FR-CV-H30K(-AT) FR-CVL-H30K 
FR-CV-H37K FR-CVL-H37K 
FR-CV-H55K FR-CVL-H55K