Netfinity 3500-M20 – Type 8657 Models 21Y, 22Y, 31Y, 32Y,
pnt0-19
IRQ found for PCnet hardware does not 
match space.c (or pnt.conf)! 
 
Explanation:  This is a warning message 
referring to the interrupt request (IRQ) that the 
SunSoft Solaris driver found in the system.   
Action:  Ignore this message if you are sure 
that this is what you want to do.  Otherwise, run 
the NETCONFIG program to match the 
hardware settings
pnt0-20
add_intr_handler failed!  Unknown interrupt 
type.  
 
Explanation:  The interrupt request (IRQ) that 
was specified, or the IRQ that was found, 
conflicts with other devices in the server.  
Action: 
 Modify the hardware settings.
 Run the NETCONFIG program to search 
for another Ethernet controller.
pnt0-21
add_intr_handler failed!  Out of range 
interrupt number.  
 
Explanation:  The interrupt request (IRQ) that 
was specified, or the IRQ that was found, 
conflicts with other devices in the server.   
Action:
 
Modify the hardware settings.
Run the NETCONFIG program to search 
for another Ethernet controller.
pnt0-22
add_intr_handler failed!  Out of range IPL. 
Explanation:  The interrupt request (IRQ) that 
was specified, or the IRQ that was found, 
conflicts with other devices in the server.   
Action:  Modify the hardware settings.  Run 
the NETCONFIG program to search for 
another Ethernet controller.
pnt0-23
add_intr_handler failed!  Vector already 
occupied.  
 
Explanation:  The interrupt request (IRQ) that 
was specified, or the IRQ that was found, 
conflicts with other devices in the server.   
Action:  Modify the hardware settings.
Table 5. UNIX LLI driver messages for the Ethernet 
controller