IBM 21Y 사용자 설명서
30
Netfinity 3500-M20 – Type 8657 Models 21Y, 22Y, 31Y, 32Y,
pnt0-19
IRQ found for PCnet hardware does not
match space.c (or pnt.conf)!
match space.c (or pnt.conf)!
Explanation: This is a warning message
referring to the interrupt request (IRQ) that the
SunSoft Solaris driver found in the system.
Action: Ignore this message if you are sure
that this is what you want to do. Otherwise, run
the NETCONFIG program to match the
hardware settings
referring to the interrupt request (IRQ) that the
SunSoft Solaris driver found in the system.
Action: Ignore this message if you are sure
that this is what you want to do. Otherwise, run
the NETCONFIG program to match the
hardware settings
pnt0-20
add_intr_handler failed! Unknown interrupt
type.
type.
Explanation: The interrupt request (IRQ) that
was specified, or the IRQ that was found,
conflicts with other devices in the server.
Action:
was specified, or the IRQ that was found,
conflicts with other devices in the server.
Action:
•
Modify the hardware settings.
•
Run the NETCONFIG program to search
for another Ethernet controller.
for another Ethernet controller.
pnt0-21
add_intr_handler failed! Out of range
interrupt number.
interrupt number.
Explanation: The interrupt request (IRQ) that
was specified, or the IRQ that was found,
conflicts with other devices in the server.
Action:
was specified, or the IRQ that was found,
conflicts with other devices in the server.
Action:
•
Modify the hardware settings.
•
Run the NETCONFIG program to search
for another Ethernet controller.
for another Ethernet controller.
pnt0-22
add_intr_handler failed! Out of range IPL.
Explanation: The interrupt request (IRQ) that
was specified, or the IRQ that was found,
conflicts with other devices in the server.
Action: Modify the hardware settings. Run
the NETCONFIG program to search for
another Ethernet controller.
was specified, or the IRQ that was found,
conflicts with other devices in the server.
Action: Modify the hardware settings. Run
the NETCONFIG program to search for
another Ethernet controller.
pnt0-23
add_intr_handler failed! Vector already
occupied.
occupied.
Explanation: The interrupt request (IRQ) that
was specified, or the IRQ that was found,
conflicts with other devices in the server.
Action: Modify the hardware settings.
was specified, or the IRQ that was found,
conflicts with other devices in the server.
Action: Modify the hardware settings.
Table 5. UNIX LLI driver messages for the Ethernet
controller
controller