Managing trunks 
360
Inserting and absorbing digits 
12
2. In the Digit Treatment field, type 
insertion
.
This field tells the switch to add digits to the incoming digit string. These 
digits are always added at the beginning of the string.
3. In the Digits field, type 
6
.
For insertion, this field defines the specific digits to insert. The switch will 
add a “6” to the front of the digit strings delivered with incoming calls. For 
example, if the central office delivers the string “4444,” DEFINITY ECS 
will change it to “64444,” an extension that fits your dial plan.
4. In the Expected Digits field, type 
4
.
This field tells the switch how many digits the central office sends.
NOTE:
The Expected digits field doesn’t appear on the screen for tie trunk 
groups.
5. Press 
ENTER
 to save your changes.
If your service provider sends 7 digits but you only need 5, you need to absorb the 
first 2 digits in the digit string. To absorb digits:
1. Type change trunk-group 5 and press 
ENTER
.
The 
Trunk Group
 screen appears.
2. In the Digit Treatment field, type 
absorption
.
This field tells the switch to remove digits from the incoming digit string. 
These digits are always removed from the beginning of the string.
3. In the Digits field, type 
2
.
 
                                TRUNK GROUP                                      
                                                                                 
Group Number: 5  
Group Type: did 
CDR Reports: y
Group Name: Incoming calls
COR: 85
TN: 1
TAC: 105
Country: 1 
Auth Code? n 
                                                                                 
TRUNK PARAMETERS                                                                 
Trunk Type: wink-start
Incoming Rotary Timeout(sec): 5 
Incoming Dial Type: tone
Trunk Termination: rc
 
Disconnect Timing(msec): 500
Digit Treatment: insertion  
Digits: 6
Expected Digits: 4
Sig Bit Inversion: none
Extended Loop Range? n 
Trunk Gain: high 
Drop Treatment: silence
                                                                                 
 Disconnect Supervision - In? y