Lucent Technologies Release 7 Manuel D’Utilisation

Page de 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-643
DS1-FAC (DS1 Facility) 
9
For TN1654 DS1 CONV boards, this field is display only. It can not be 
administered. The TN1654 has option switches located on the component side of 
the circuit pack. If T1 operation is selected via the first switch, four additional 
switches are used to select the framing mode for each facility. Each facility can 
be set to either D4 or ESF framing. The framing mode field will display what the 
switch is set to for the DS1 facility.
Framing Mode is applicable only to T1 operation, thus this field will not appear on 
the fiber-link form if the TN1654 DS1 CONV is administered for a bit rate of 2.048 
Mbps.
Line Termination
This field displays the line termination for the DS1 facility on the TN1654 DS1 
Converter circuit pack. This field is display only. It can not be administered. The 
TN1654 has option switches located on the component side of the circuit pack. If 
E1 operation is selected via the first switch, four additional switches are used to 
select the line termination for each facility. Each facility can be set to either CEPT 
75 ohm coaxial or 120 ohm CEPT twisted pair. This line termination field will 
display what the switch is set to for the DS1 facility.
Line Termination is applicable only to E1 operation, thus this field will not appear 
on the fiber-link form if the TN1654 DS1 CONV is administered for a bit rate of 
1.544 Mbps
Facility Circuit ID
These fields are used to specify a unique alpha-numeric name up to 40 
characters long for each DS1 facility. This field will be displayed for each facility 
whose 
Facility Installed? field is set to yes.