Lucent Technologies Release 7 Manuel D’Utilisation

Page de 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1119
M/T-DIG (Maintenance/Test Digital Port) 
9
Table 9-445.
TEST #566 Hook State Inquiry 
Error 
Code
Test Result
Description/ Recommendation
1
ABORT
Switch hook audit timed out. No response was received from the circuit 
pack for information about the switch hook state.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, replace the circuit pack and repeat the 
test.
3. If the test continues to abort, escalate the problem.
2100
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
Any
FAIL
Internal System Error This test should never return a failure.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail reset the circuit pack via the busy-out 
board UUCSSreset board UUCSSrelease board UUCSS 
command sequence.
3. Retry the command at 1-minute intervals a maximum of 5 times.
4. If the test continues to fail, escalate the problem.
PASS
Call processing and Maintenance/Test Digital Port maintenance software 
agree on the Maintenance/Test Digital Port hook state.
Continued on next page