Lucent Technologies Release 7 Manuel D’Utilisation
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1119
M/T-DIG (Maintenance/Test Digital Port)
9
Table 9-445.
TEST #566 Hook State Inquiry
Error
Code
Code
Test Result
Description/ Recommendation
1
ABORT
Switch hook audit timed out. No response was received from the circuit
pack for information about the switch hook state.
pack for information about the switch hook state.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, replace the circuit pack and repeat the
test.
3. If the test continues to abort, escalate the problem.
2100
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
Any
FAIL
Internal System Error This test should never return a failure.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail reset the circuit pack via the busy-out
board UUCSS, reset board UUCSS, release board UUCSS
command sequence.
command sequence.
3. Retry the command at 1-minute intervals a maximum of 5 times.
4. If the test continues to fail, escalate the problem.
PASS
Call processing and Maintenance/Test Digital Port maintenance software
agree on the Maintenance/Test Digital Port hook state.
agree on the Maintenance/Test Digital Port hook state.
Continued on next page