Maintenance Object Repair Procedures
9-1121
M/T-PKT (Maintenance/Test Packet Bus Port)
9
Hardware Error Log Entries and Test to Clear
Values
Values
Notes:
a. This error indicates a hardware failure with the port circuitry which
provides the Packet Bus maintenance functions. Replace the
Maintenance/Test circuit pack if the alarm is not resolved by the test
command above.
Maintenance/Test circuit pack if the alarm is not resolved by the test
command above.
b. The port has been busied out via the busyout port UUCSSpp command.
c. This error indicates that the Maintenance/Test Packet Bus Port has
reconfigured the Packet Bus by swapping a bad lead to a spare. Note that
this error is sent up whenever the Maintenance/Test Packet Bus Port is
initialized (since the Packet Bus Port reconfigures the Packet Bus to
whatever state it determines the Packet Bus is in). This will occur if the
circuit pack is inserted, if the system is restarted, or if the port is released
from a busyout state. Therefore, it is normal for this error to be present in
the error log.
this error is sent up whenever the Maintenance/Test Packet Bus Port is
initialized (since the Packet Bus Port reconfigures the Packet Bus to
whatever state it determines the Packet Bus is in). This will occur if the
circuit pack is inserted, if the system is restarted, or if the port is released
from a busyout state. Therefore, it is normal for this error to be present in
the error log.
If the M/T-PKT reconfigures the Packet Bus 6 times within 15 minutes, a
Minor alarm is raised indicating that either Packet Bus maintenance
functions are not operating correctly, or many changes are taking place on
the Packet Bus (circuit pack insertions or removals). If the system has
been in a stable state for more than 15 minutes, try the following
procedure:
Minor alarm is raised indicating that either Packet Bus maintenance
functions are not operating correctly, or many changes are taking place on
the Packet Bus (circuit pack insertions or removals). If the system has
been in a stable state for more than 15 minutes, try the following
procedure:
M/T-PKT Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port UUCSSpp
1 (a)
41018
none
MINOR
ON
test port UUCSSpp l r 3
18 (b)
0
busyout port
UUCSSpp
UUCSSpp
WARNING
OFF
release port UUCSSpp
257 (c)
Any
none
MINOR
ON
513 (d)
Any
Packet Bus Port
Health Inquiry
Test (#567)
Health Inquiry
Test (#567)
MINOR
ON
test port UUCSSpp r 3