9-1123
M/T-PKT (Maintenance/Test Packet Bus Port) 
9
Clear Error Counters (#270)
This test is not an actual test in the strict sense of the word. Many circuit packs 
have counters in the Angel firmware. The circuit pack’s Angel continuously runs 
port self-tests on idle ports and keeps track of any errors it detects by 
incrementing a firmware counter. When the counter value reaches some preset 
threshold, the Angel sends a single CCMS (Control Channel Message Set) error 
message uplink to the SPE. No more error messages of that type are sent uplink 
until the SPE sends a downlink message to clear the counter. This strategy keeps 
a failed port/circuit pack from flooding the SPE with a continuous string of 
identical error messages). This test is used to clear the counter, so that if the port 
continues to fail during or after SPE-demanded testing, the Angel will send a 
message to indicate that fact.
This test is only used to send a downlink message to the Angel on the 
Maintenance/Test circuit pack. Since the Angel normally provides no uplink 
response to this message, this test should never abort or fail.
Packet Bus Port Health Inquiry Test (#567)
This test verifies that the Packet Bus fault detection maintenance function of the 
M/T-PKT is functioning properly. This is done by having the M/T-PKT perform a 
self-test. If this self-test passes, then the Packet Bus Port Health Inquiry Test 
passes. If the self-test fails, or the SPE cannot communicate with the M/T-PKT, 
then the test fails
Table 9-446.
TEST #270 Clear Error Counters 
Error 
Code
Test Result
Description/ Recommendation
Any
ABORT
This test should never abort.
Any
FAIL
This test should never fail.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, escalate the problem.
PASS
The message to clear the Maintenance/Test circuit pack’s counter for 
Background Maintenance Failures has been sent.
Continued on next page