Echo SRM-410U Manuel D’Utilisation

Page de 36
G
RASS
 T
RIMMER
/B
RUSH
 C
UTTER
O
PERATOR
'
S
 M
ANUAL
21
STARTING
 
WARM
 
ENGINE
1.  Press the decompression device (E).
2. Stop Switch
 
Move stop switch (A) forward away from the STOP position.
3. Purge Bulb
     Pump purge bulb (C) until fuel is visible in the "Clear" fuel return 
line.
4. Recoil 
Starter    
Lay the unit on a fl at area and keep movable attachment parts clear 
of all obstacles. Hold unit fi rmly and rapidly pull the recoil starter 
handle (D) until the engine fi res.
NOTE
If engine does not start after 5 pulls, use Cold Start Procedure. 
STOPPING
 
ENGINE
1.  Release throttle trigger and allow to run at an idle speed. 
2.  Slide ignition switch to “STOP” position.
E
A
D
C
D