Message
Meaning
Action Required
HH
OHH
Overheat protection (spa is shut-
down). One sensor has detected 
118˚F (48˚C) at the heater.
DO NOT ENTER THE WATER!
Remove the spa cover and allow spa to cool below 
107˚F (42˚C).  Press any button on the topside display 
to reset spa.  If spa will not reset after spa has cooled, 
turn off power for approximately 30 seconds and then 
turn power back on. If display message is repeated then 
shut the power off to the spa and call your dealer or 
service organization.
Pr
When your spa is first actuated, it 
will go into priming mode.
The priming mode will last for up to four minutes and 
then the spa will begin to heat and maintain the water 
temperature in the Standard mode.
SF
Safety Suction. Spa is shut down. The display will show SF when a vacuum switch closes. 
All functions will turn off and the system will be disabled 
until a panel button is pressed.
SL
Indicates heater is in Sleep Mode. None.
SA
Sb
SNA
Snb
Spa is shut down. The sensor 
that is plugged into the sensor 
“A” or “B” jack is not working.
If the problem persists, contact your dealer or service 
organization. (May appear temporarily in an overheat 
situation and disappear when the heater cools.)
Sns
Sn
Sensors are out of balance.
If  this  is  alternating  with  the 
• 
temperature, it may just be a 
temporary condition.
If the display shows only this 
• 
message  (periodically  blink-
ing), the spa is shut down.
Contact your dealer or service organization.
ST
Indicates heater is in Standard 
Mode.
None.
Stby
Pressing a button combination 
on the user panel has activated 
Standby Mode.
Press any button to leave Standby Mode and return to 
normal operation.