Cal Spas 6200 Manuel D’Utilisation

Page de 52
2008 Portable Spa Owner’s Manual 
Page 13
LTR20081000, Rev. B
Operating Your Spa
When first powered up, the 9800 electronic 
system will perform a self-diagnostic check 
and  then  it  will  automatically  heat  to  and 
maintain  a  temperature  of  100°F  (37.5°C) 
until  you  change  the  set  temperature  as 
listed  in  the  “Temperature  Adjustment” 
section below.
These instructions will describe features and 
options that your particular spa may not be 
equipped with.
Initial Start-up
When  your  spa  is  first  powered  up,  it  displays  some 
configuration  codes  and  then  goes  into  priming  mode 
(Pr will appear on the display panel). This mode lasts up 
to four minutes and then the spa begins to heat to its pre 
-programmed temperature of 100°F.
Temperature Adjustment
(Range 80°F to 104°F, 26°C to 40°C)
The start-up temperature is set at 100°F (37.5°C). The 
last  measured  temperature  is  constantly  displayed 
on  the  control  panel.  Note  that  the  last  measured  spa 
temperature  is  displayed.  The  displayed  temperature 
will be updated when the pump has been running for at 
least two minutes.
Press the “UP” or “DOWN” buttons once to display the 
set  temperature.  Each  time  either  button  is  pressed 
again,  the  set  temperature  will  increase  or  decrease 
depending  on  which  button  is  pressed.  After  three 
seconds, the control panel will automatically display the 
last measured spa temperature.
Time
When  time  hasn’t  been  programmed,  the  “TIME”  icon 
flashes.  To  set  the  time,  press  the  “TIME”  button  and 
then  the  “MODE/PROG”  button.  Use  the  “UP”  and 
“DOWN” buttons to adjust time.  See the next page for 
more detailed instructions. 
Standard,  Economy,  Sleep,  and  Standby 
Modes
Mode/Prog:  This  button  is  used  to  switch  between 
standard, economy, and sleep modes.
Press “MODE/PROG” to enter mode programming.
Press  the  “DOWN”  button  to  cycle  through  to  the 
desired mode.
Press “MODE/PROG” to confirm selection.
1.
2.
3.
Standard  Mode:  This  is  programmed  to  maintain  the 
desired  temperature.  Note  that  the  last  measured  spa 
temperature  displayed  is  current  only  when  the  pump 
has been running for at least two minutes. The “STAND” 
icon will display until the mode is changed.
Economy Mode: Economy mode heats the spa to the 
set  temperature  only  during  filter  cycles.  The  “ECON” 
icon will display until the mode is changed. Pressing the 
“JETS 1” button while in economy mode puts the spa in 
standard-in-economy  mode,  which  operates  the  same 
as  standard  mode  but  reverts  back  to  economy  mode 
automatically after one hour.  During this time, pressing 
the “MODE/PROG” button will revert to economy mode 
immediately.
Sleep Mode: Sleep mode heats the spa to within 20°F 
(11°C) of the set temperature only during filter cycles. The 
“SLEEP” icon will display until the mode is changed.
Standby Mode: Pressing “Warm” or “Cool” then “JETS 
2” will turn off all spa functions temporarily. This is helpful 
when changing a filter. Pressing any button resets the 
spa.
Jets 1
Press the “JETS 1” button once to turn pump 1 on or off 
and to shift between low and high speeds if equipped. 
If  left  running,  the  low  speed  turns  off  after  two  hours 
and the high speed turns off after 15 minutes. On non-
circulation systems, the low speed of pump 1 runs when 
the blower or any other pump is on. It may also activate 
for at least two minutes every 30 minutes to detect the 
spa temperature and then to heat to the set temperature if 
needed, depending upon the mode. When the low speed 
turns on automatically, it cannot be deactivated from the 
panel; however, the high speed may be started.
9800 Electronic Control Operation