Cal Spas 6200 Manuel D’Utilisation

Page de 52
2008 Portable Spa Owner’s Manual 
Page 11
LTR20081000, Rev. B
Operating Your Spa
Light 
Press the Light button to turn on the light. Press it once 
again  to  turn  the  light  off. All  optional  lighting  such  as 
the control panel light and cabinet perimeter lighting is 
controlled  by  the  Light  button  and  will  turn  on  and  off 
with the spa light.
Option
Press the Option button to turn on the pump 2. Press it 
once again to turn off the pump 2 (6200 Controls only).
6300 Controls - Pump 2 and Pump 3 
Sequence
Press  Option  button  once  to  activate  high  speed 
pump 2.
Press  Option  button  twice  to  activate  high  speed 
pump 3 and high speed pump 2
Press 3 times to activate pump 3 hi speed only
Press 4 times to turn pumps off
Automatic Time outs
These  features  will  automatically  turn  themselves  off 
during periods of continuous use:
Low speed pump 
 
After 4 hours
High speed pumps   
After 15 minutes
Optional circulation pump 
After 15 minutes
Optional turbo 
 
After 15 minutes
Spa light 
 
 
After 15 minutes
Setting Filtration Cycles
Your spa is programmed to filter twice a day.  The first 
cycle will begin 6 minutes after the spa is turned on and the 
second cycle 12 hours later.  The factory has programmed 
the cycle to last for 2 hours but this can be switched to 
4,  6,  or  8  hours  depending  on  your  requirements.    To 
set  filtration  time,  turn  off  the  power  to  the  spa  at  the 
time of day you would like one of the filtration cycles to 
begin then turn back on after 30 seconds.  When power 
has been restored, press the Temp button then the Jets 
button.  Press Temp
 button again to change the filtering 
cycle duration.  When desired duration is selected press 
the Jets button to exit.
At the beginning of each filtering cycle the Turbo system 
will  run for approximately  30 seconds.  The low speed 
pump will run for the duration of the filtering cycle and if 
an Ozone system is installed it will be activated.  During 
filtering, FC will appear on the main display.
Diagnostic Messages
Message
Meaning
--
Spa temperature is unknown.  After pump has been running for 2 minutes temperature will be 
displayed.
HH
Overheat protection (spa is shutdown) DO NOT ENTER THE WATER!  One sensor has detected 
118˚F (48˚C) at the heater.  Remove the spa cover and allow spa to cool below 107˚F (42˚C).  
Press any button on the topside display to reset spa.  If spa will not reset after spa has cooled, 
turn off power for approximately 30 seconds and then turn power back on.  If display message is 
repeated then shut the power off to the spa and call your dealer or service organization.
OH
Overheat protection (spa is shutdown) DO NOT ENTER THE WATER! If the spa has reached 
110˚F (43˚C), remove the spa cover to cool the water. At 107˚F (42˚C), the spa should reset 
itself.  If the spa does not reset, then shut the power off to the spa, wait 30 seconds and restore 
power to spa.   If display message is repeated then shut the power off to the spa and call your 
dealer or service organization.
IC
A possible ice condition exists within the spa.  No action is required, the pump will automatically 
activate.
SA or Sb
Spa is shut down.  Spa has detected that one of the sensors is not operating properly.  One 
of these may display briefly during overheat then disappear when overheat situation has been 
resolved.  Call your dealer or service organization if message does not go away.
Sn
Sensor (Spa is shut down). The high limit or water temperature sensors are not working correctly. 
Call your dealer or service organization.